END-OF-LIFE DISPOSAL

Dispose of the system in compliance with the established legislation in the country of use.

15 

EU DECLARATION OF CONFORMITY

The declaration of conformity is available at the website www.aragnet.com, in the relevant section.

14 

GUARANTEE TERMS

1.  ARAG s.r.l. guarantees this apparatus for a period of 360 days (1 year) from the date of sale to the client user (date of the goods delivery 

note).

 

The components of the apparatus, that in the unappealable opinion of ARAG are faulty due to an original defect in the material or 

production process, will be repaired or replaced free of charge at the nearest Assistance Center operating at the moment the request for 

intervention is made. The following costs are excluded:

-  disassembly and reassembly of the apparatus from the original system;

-  transport of the apparatus to the Assistance Center.

2.  The following are not covered by the guarantee:

-  damage caused by transport (scratches, dents and similar);

-  damage due to incorrect installation or to faults originating from insufficient or inadequate characteristics of the electrical system, or to 

alterations resulting from environmental, climatic or other conditions;

-  damage due to the use of unsuitable chemical products, for spraying, watering, crop sprayer or any other crop treatment, that may 

damage the apparatus;

-  malfunctioning caused by negligence, mishandling, lack of know how, repairs or modifications carried out by unauthorized personnel;

-  incorrect installation and regulation;

-  damage or malfunction caused by the lack of ordinary maintenance, such as cleaning of filters, nozzles, etc.;

-  anything that can be considered to be normal wear and tear;

3.  Repairing the apparatus will be carried out within time limits compatible with the organizational needs of the Assistance Center.

 

No guarantee conditions will be recognized for those units or components that have not been previously washed and cleaned to remove 

residue of the products used;

4.  Repairs carried out under guarantee are guaranteed for one year (360 days) from the replacement or repair date.

5.  ARAG will not recognize any further expressed or intended guarantees, apart from those listed here.

 

No representative or retailer is authorized to take on any other responsibility relative to ARAG products.

 

The period of the guarantees recognized by law, including the commercial guarantees and allowances for special purposes are limited, in 

length of time, to the validities given here. 

 

In no case will ARAG recognize loss of profits, either direct, indirect, special or subsequent to any damage.

6.  The parts replaced under guarantee remain the property of ARAG.

7.  All safety information present in the sales documents regarding limits in use, performance and product characteristics must be transferred 

to the end user as a responsibility of the purchaser.

8.  Any controversy must be presented to the Reggio Emilia Law Court.

Summary of Contents for 863T Series

Page 1: ...INSTALLATION USE AND MAINTENANCE SERIES 863T 873T BOOM SECTION VALVES WITH FORK COUPLING ...

Page 2: ...s 4 6 2 2 Pressure relief manifolds 4 6 3 Overall dimensions SERIES 863T 5 6 4 Overall dimensions SERIES 873T 6 6 5 Attachment 7 7 Hydraulic connections 7 8 Wiring connections 9 8 1 General precautions for a correct harness position 9 8 2 Wiring connections 9 9 Use 11 9 1 Controls 11 9 2 Calibrating the metered by passes 11 9 2 1 Metered by pass calibration tables 12 9 3 LED signals 13 10 Time to ...

Page 3: ...d in the system The use of such substances is made under the full responsibility of the operator who therefore must follow the safety measures indicated by the fluid manufacturer on the package and wear suitable personal safety equipment gloves coverall boots helmet etc in compliance with the law provisions ARAG may not in any way be held responsible for accidents or damage to persons animals or o...

Page 4: ...elements to form electric control units with different configurations ref corresponding manual Additional couplings O rings and other additional parts valves filters flowmeters etc must be ordered separately general Arag catalog when choosing the items make sure that preset connections are correct for the valves section 6 3 6 4 Pompa Filtro Linea scarico Linea pressione Linea aspirazione Cisterna ...

Page 5: ...63T 127 mm 75 mm 52 mm 48 mm 127 mm 62 5 mm 75 mm 52 mm 62 5 mm 48 mm 43 5 mm 43 5 mm 195 mm 81 mm 218 mm 81 mm 57 mm 57 mm Center distance of the valves T5 T5 T3 T5 T5 T1 T1 T3 125 mm 94 mm 40 mm Position of the drilling points for the attachment bolts ...

Page 6: ...RALL DIMENSIONS 136 mm 75 mm 61 mm 65 5 mm 41 5 mm 67 mm Center distance of the valves 6 4 Overall dimensions SERIES 873T 202 mm 99 mm T6 T6 T4 134 mm 99 mm Position of the drilling points for the attachment bolts ...

Page 7: ...an those described TE M8 5 16 UN Fig 2 INSTALLATION CONTINUES 1 2 1 2 Connect the components with fork coupling as follows Apply O ring lubricant Position the O ring ON THE MALE CONNECTION OF ALL THE COUPLINGS make sure that the position is correct The couplings shown are indicative The maximum operating pressure of the valve is indicated in the technical data sheet of the product ONLY after all t...

Page 8: ...aximum operating pressure of the valve is indicated in the technical data sheet of the product ONLY after all the hydraulic connections of the circuit to the relevant pipes have been made put the system under pressure ONLY WITH CLEAN WATER FIRST to make sure that the connections are not leaking If for any reason the pipes leak at connection points apply PTFE tape to improve sealing ASSEMBLING AND ...

Page 9: ...oo hard or bending them the contacts may be damaged and system operation may be compromised Use ONLY the cables and accessories indicated in the catalog having technical features suitable for the use to be made of them 8 2 Wiring connections The 863T and 873T valves have been designed to be connected to ARAG control devices computer monitor control boxes The cables required for the connections are...

Page 10: ... valve closes 2 wire operation Valve open 1 2 1 2 Valve closed 1 2 3 1 2 1 2 Opening closing movement obtained by reversing the power supply polarity with a dual switch SERIES 863T 873T CANBUS 1 2 3 4 12 Vdc power supply always connected 3 wire operation Valve open 1 2 4 1 3 1 2 4 3 CONTROL POWER SUPPLY Valve closed 1 2 4 1 3 1 2 4 3 CONTROL POWER SUPPLY 12 Vdc power supply always connected By sup...

Page 11: ...pressure to the predefined working value 1 Close a section valve by activating the corresponding switch on the control device OFF position 2 Adjust the corresponding metered by pass by turning the knob until restoring the previously set pressure value with all the section valves open 3 Open and close the section valve by properly activating the corresponding switch on the control device check that...

Page 12: ...tered by pass calibration tables NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF USE ...

Page 13: ...HT COLOR STATUS OFF The valve is not powered ORANGE STEADY ON The valve is being turned on DURING THE 10 SECONDS AFTER TURNING ON GREEN BLINKING Waiting to acquire a CANBUS address After 10 seconds the LED turns green steady on even if the address has not yet been acquired GREEN STEADY ON The valve is configured and working ORANGE BLINKING The valve firmware is being updated RED BLINKING ERROR The...

Page 14: ...the sealing and therefore cause leaks 10 1 Section valves MAINTENANCE DIAGNOSTICS REPAIRS 10 1 1 Seal seat replacement Remove the fork and the motor shaft unit from the seat 1 and 2 Slide seat and O ring out and replace them CASE 1 valve with seat and O ring replace with cage and O ring CASE 2 valve with cage and O ring replace with new cage and O ring Reposition motor shaft unit 3 Reposition the ...

Page 15: ... If the problem persists contact your nearest Service Center Wrong wiring harness connection Check the connections and the cables Power supply voltage lower than the minimum value Make sure that the harnesses are suitable for the system Green steady on Geared motor broken Replace the geared motor The CAN BUS address assigned to the valve is wrong Repeat the address assignment procedure The sent co...

Page 16: ... 5 bar 7 PSI 50 l min 13 US GPM Maximum operating pressure 20 bar 290 PSI Type ON OFF BY PASS ELECTRICAL FEATURES Valve status LED Integrated motor control and management electronics Internal resettable fuse disconnect the power supply for 20 seconds to reset Power supply voltage 9 16 Vdc Protection against polarity inversion Yes Protection against short circuit Yes Absorption 12 Vdc 0 5 A average...

Page 17: ...0 l min 48 US GPM HI FLOW version Maximum operating pressure 12 bar 174 PSI Type ON OFF ELECTRICAL FEATURES Valve status LED Integrated motor control and management electronics Internal resettable fuse disconnect the power supply for 20 seconds to reset Power supply voltage 9 16 Vdc Protection against polarity inversion Yes Protection against short circuit Yes Absorption 12 Vdc 0 5 A average absor...

Page 18: ...aused by negligence mishandling lack of know how repairs or modifications carried out by unauthorized personnel incorrect installation and regulation damage or malfunction caused by the lack of ordinary maintenance such as cleaning of filters nozzles etc anything that can be considered to be normal wear and tear 3 Repairing the apparatus will be carried out within time limits compatible with the o...

Page 19: ......

Page 20: ...ladio 5 A Tel 39 0522 622011 Fax 39 0522 628944 http www aragnet com info aragnet com Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time Always refer to the Internet address www aragnet com ...