7
ASSEMBLING AND FIXING
THE COUPLINGS
CONNECTING THE VALVES
7
HYDRAULIC CONNECTIONS
6.5
Attachment
The valve is factory set to be attached using bolts of the indicated type:
- Insert the bolts into their respective seats and turn them to the stop position to prevent them from coming out.
It is also recommended to use a flat washer of suitable diameter (Ø 8 ISO 7089).
- Screw the nuts and tighten them firmly:
TIGHTENING TORQUE 4 Nm +/-0.5 Nm
No other types of coupling are permitted than those described.
TE M8
5/16 UN
Fig. 2
INSTALLATION
CONTINUES >>>
1
2
1
2
Connect the components with fork coupling as follows:
- Apply O-ring lubricant.
- Position the O-ring ON THE MALE CONNECTION OF ALL THE COUPLINGS (make
sure that the position is correct).
- The couplings shown are indicative.
The maximum operating pressure of the valve is indicated in the technical data
sheet of the product.
ONLY after all the hydraulic connections of the circuit to the relevant pipes have
been made, put the system under pressure ONLY WITH CLEAN WATER FIRST to
make sure that the connections are not leaking.
If, for any reason, the pipes leak at connection points, apply PTFE tape to improve sealing.
3