10
INSTALLATION
SERIES 863T - 873T
3-wire operation
Valve open
1
2
3
1
2
3
1
2
1
2
CONTROL
POWER SUPPLY
Valve closed
1
2
3
1
2
3
1
2
1
2
CONTROL
POWER SUPPLY
• 12 Vdc power supply always connected.
• By supplying the control voltage (12 Vdc
on PIN 3), the valve opens.
• By removing the control voltage (PIN 3),
the valve closes.
2-wire operation
Valve open
1
2
3
1
2
3
1
2
1
2
Valve closed
1
2
3
1
2
3
1
2
1
2
• Opening/closing movement obtained by
reversing the power supply polarity with a
dual switch.
SERIES 863T - 873T CANBUS
1
2
3
4
• 12 Vdc power supply always connected.
3-wire operation
Valve open
1
2
4
1
3
1
2
4
3
CONTROL
POWER SUPPLY
Valve closed
1
2
4
1
3
1
2
4
3
CONTROL
POWER SUPPLY
• 12 Vdc power supply
always connected.
• By supplying the control
voltage (12 Vdc on PIN 4),
the valve opens.
• By removing the control
voltage (PIN 4), the valve
closes.