background image

17

TECHNICAL DATA

12.2 

873T section valves

SERIES 873T

SERIES 873T CAN

-BUS

ELECTRICAL FEATURES

• 

Valve status LED.

• 

Internal resettable fuse (disconnect the power supply for 20 seconds to reset).

• 

Power supply voltage 

9 ÷ 16 Vdc

• 

Protection against polarity inversion 

Yes

• 

Protection against short-circuit 

Yes

• 

Absorption @ 12 Vdc 

0.5 A (average absorption)

• 

The motor absorbs current only during valve movement

ENVIRONMENTAL FEATURES

• 

Operating temperature 

0 °C ÷ +60 °C / 32 °F ÷ +140 °F

• 

Storage temperature 

0 °C ÷ +60 °C / 32 °F ÷ +140 °F

PHYSICAL FEATURES

• 

Structure in fiber glass reinforced Nylon®

• 

Internal parts in Delrin® and AISI 303 stainless steel

• 

Seals in Viton®

• 

On/Off activation time 

0.6 s 

 

1.8 s

• 

Flowrate @ 0.5 bar / 7 PSI 

120 l/min / 32 US GPM 

 

180 l/min / 48 US GPM (HI-FLOW version)

• 

Maximum operating pressure 

12 bar / 174 PSI

• 

Type ON/OFF

ELECTRICAL FEATURES

• 

Valve status LED.

• 

Integrated motor control and management electronics.

• 

Internal resettable fuse (disconnect the power supply for 20 seconds to reset).

• 

Power supply voltage 

9 ÷ 16 Vdc

• 

Protection against polarity inversion 

Yes

• 

Protection against short-circuit 

Yes

• 

Absorption @ 12 Vdc 

0.5 A (average absorption)

• 

Can-Bus connection port 

speed 250 Kbit/sec 

for valve control and diagnostics 

A-net protocol / Can-Bus protocol 

ENVIRONMENTAL FEATURES

• 

Operating temperature 

0 °C ÷ +60 °C / 32 °F ÷ +140 °F

• 

Storage temperature 

0 °C ÷ +60 °C / 32 °F ÷ +140 °F

PHYSICAL FEATURES

• 

Structure in fiber glass reinforced Nylon®

• 

Internal parts in Delrin® and AISI 303 stainless steel

• 

Seals in Viton®

• 

On/Off activation time 

0.6 s

• 

Flowrate 0.5 bar / 7 PSI 

120 l/min / 32 US GPM

• 

 

180 l/min / 48 US GPM (HI-FLOW version)

• 

Maximum operating pressure 

12 bar / 174 PSI

• 

Type ON/OFF

Summary of Contents for 863T Series

Page 1: ...INSTALLATION USE AND MAINTENANCE SERIES 863T 873T BOOM SECTION VALVES WITH FORK COUPLING ...

Page 2: ...s 4 6 2 2 Pressure relief manifolds 4 6 3 Overall dimensions SERIES 863T 5 6 4 Overall dimensions SERIES 873T 6 6 5 Attachment 7 7 Hydraulic connections 7 8 Wiring connections 9 8 1 General precautions for a correct harness position 9 8 2 Wiring connections 9 9 Use 11 9 1 Controls 11 9 2 Calibrating the metered by passes 11 9 2 1 Metered by pass calibration tables 12 9 3 LED signals 13 10 Time to ...

Page 3: ...d in the system The use of such substances is made under the full responsibility of the operator who therefore must follow the safety measures indicated by the fluid manufacturer on the package and wear suitable personal safety equipment gloves coverall boots helmet etc in compliance with the law provisions ARAG may not in any way be held responsible for accidents or damage to persons animals or o...

Page 4: ...elements to form electric control units with different configurations ref corresponding manual Additional couplings O rings and other additional parts valves filters flowmeters etc must be ordered separately general Arag catalog when choosing the items make sure that preset connections are correct for the valves section 6 3 6 4 Pompa Filtro Linea scarico Linea pressione Linea aspirazione Cisterna ...

Page 5: ...63T 127 mm 75 mm 52 mm 48 mm 127 mm 62 5 mm 75 mm 52 mm 62 5 mm 48 mm 43 5 mm 43 5 mm 195 mm 81 mm 218 mm 81 mm 57 mm 57 mm Center distance of the valves T5 T5 T3 T5 T5 T1 T1 T3 125 mm 94 mm 40 mm Position of the drilling points for the attachment bolts ...

Page 6: ...RALL DIMENSIONS 136 mm 75 mm 61 mm 65 5 mm 41 5 mm 67 mm Center distance of the valves 6 4 Overall dimensions SERIES 873T 202 mm 99 mm T6 T6 T4 134 mm 99 mm Position of the drilling points for the attachment bolts ...

Page 7: ...an those described TE M8 5 16 UN Fig 2 INSTALLATION CONTINUES 1 2 1 2 Connect the components with fork coupling as follows Apply O ring lubricant Position the O ring ON THE MALE CONNECTION OF ALL THE COUPLINGS make sure that the position is correct The couplings shown are indicative The maximum operating pressure of the valve is indicated in the technical data sheet of the product ONLY after all t...

Page 8: ...aximum operating pressure of the valve is indicated in the technical data sheet of the product ONLY after all the hydraulic connections of the circuit to the relevant pipes have been made put the system under pressure ONLY WITH CLEAN WATER FIRST to make sure that the connections are not leaking If for any reason the pipes leak at connection points apply PTFE tape to improve sealing ASSEMBLING AND ...

Page 9: ...oo hard or bending them the contacts may be damaged and system operation may be compromised Use ONLY the cables and accessories indicated in the catalog having technical features suitable for the use to be made of them 8 2 Wiring connections The 863T and 873T valves have been designed to be connected to ARAG control devices computer monitor control boxes The cables required for the connections are...

Page 10: ... valve closes 2 wire operation Valve open 1 2 1 2 Valve closed 1 2 3 1 2 1 2 Opening closing movement obtained by reversing the power supply polarity with a dual switch SERIES 863T 873T CANBUS 1 2 3 4 12 Vdc power supply always connected 3 wire operation Valve open 1 2 4 1 3 1 2 4 3 CONTROL POWER SUPPLY Valve closed 1 2 4 1 3 1 2 4 3 CONTROL POWER SUPPLY 12 Vdc power supply always connected By sup...

Page 11: ...pressure to the predefined working value 1 Close a section valve by activating the corresponding switch on the control device OFF position 2 Adjust the corresponding metered by pass by turning the knob until restoring the previously set pressure value with all the section valves open 3 Open and close the section valve by properly activating the corresponding switch on the control device check that...

Page 12: ...tered by pass calibration tables NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF NOZZLE TYPE COLOR REF USE ...

Page 13: ...HT COLOR STATUS OFF The valve is not powered ORANGE STEADY ON The valve is being turned on DURING THE 10 SECONDS AFTER TURNING ON GREEN BLINKING Waiting to acquire a CANBUS address After 10 seconds the LED turns green steady on even if the address has not yet been acquired GREEN STEADY ON The valve is configured and working ORANGE BLINKING The valve firmware is being updated RED BLINKING ERROR The...

Page 14: ...the sealing and therefore cause leaks 10 1 Section valves MAINTENANCE DIAGNOSTICS REPAIRS 10 1 1 Seal seat replacement Remove the fork and the motor shaft unit from the seat 1 and 2 Slide seat and O ring out and replace them CASE 1 valve with seat and O ring replace with cage and O ring CASE 2 valve with cage and O ring replace with new cage and O ring Reposition motor shaft unit 3 Reposition the ...

Page 15: ... If the problem persists contact your nearest Service Center Wrong wiring harness connection Check the connections and the cables Power supply voltage lower than the minimum value Make sure that the harnesses are suitable for the system Green steady on Geared motor broken Replace the geared motor The CAN BUS address assigned to the valve is wrong Repeat the address assignment procedure The sent co...

Page 16: ... 5 bar 7 PSI 50 l min 13 US GPM Maximum operating pressure 20 bar 290 PSI Type ON OFF BY PASS ELECTRICAL FEATURES Valve status LED Integrated motor control and management electronics Internal resettable fuse disconnect the power supply for 20 seconds to reset Power supply voltage 9 16 Vdc Protection against polarity inversion Yes Protection against short circuit Yes Absorption 12 Vdc 0 5 A average...

Page 17: ...0 l min 48 US GPM HI FLOW version Maximum operating pressure 12 bar 174 PSI Type ON OFF ELECTRICAL FEATURES Valve status LED Integrated motor control and management electronics Internal resettable fuse disconnect the power supply for 20 seconds to reset Power supply voltage 9 16 Vdc Protection against polarity inversion Yes Protection against short circuit Yes Absorption 12 Vdc 0 5 A average absor...

Page 18: ...aused by negligence mishandling lack of know how repairs or modifications carried out by unauthorized personnel incorrect installation and regulation damage or malfunction caused by the lack of ordinary maintenance such as cleaning of filters nozzles etc anything that can be considered to be normal wear and tear 3 Repairing the apparatus will be carried out within time limits compatible with the o...

Page 19: ......

Page 20: ...ladio 5 A Tel 39 0522 622011 Fax 39 0522 628944 http www aragnet com info aragnet com Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time Always refer to the Internet address www aragnet com ...