background image

Version: 20220420 

 

 15 

2 Route cable 

 

 

Guide the cables through the hole in the bottom of the 
bracket, through the bracket. 

Leave at least 30 cm of wire for connection. 

 

Proceed with camera body mounting. 
 

BRACKET MOUNTING INSTRUCTIONS WITH CONDUIT BOX 

Another  way  to  feed  the  cables  to  the  FireCatcher  Camera  without  going  through  the  mounting  surface  can  be 
accomplished by using the Axis TQ1601-E conduit back box. The cables can be guided sideways in any direction 
through this box as illustrated below. The FireCatcher Camera is then further mounted on top of the conduit back box 
as described in the case with wall-feed cabling. 

The  conduit  box  can  be  purchased  from  your  supplier  as  "Axis  TQ1601-E  conduit  back  box".  See 

https://www.axis.com/products/axis-tq1601-e-conduit-back-box

 for more information on this product. 

1 Mount the conduit box 

 

 

Mount the conduit back box to the wall as illustrated.  

Make sure the box is mounted horizontally by using a 
spirit level. 

 

2 Route cabling and attach the mounting bracket

 

 

Guide the cables through the mounting bracket and fix 
the bracket on top of the conduit box, using the 
included Torx screws. 

 

Summary of Contents for 8000004

Page 1: ...FireCatcher Camera ACAP software version V4 00 01 Hardware part number 8000004 INSTALLATION MANUAL...

Page 2: ...ment 9 Standby power battery calculation 9 Cabling 9 Camera positioning 10 Site assessment 10 Environmental requirements 10 Camera alignment field of view 11 Installation instructions 14 Bracket mount...

Page 3: ...e device presents exterior damages do not install it and contact your supplier Notice Do not remove any label from the device Avoid exposing the FireCatcher Camera to shocks or heavy pressure Do not i...

Page 4: ...make changes to the product and manuals without prior notice Araani NV makes no warranty of any kind regarding the material contained within this document including but not limited to the implied war...

Page 5: ...be answered immediately your reseller will forward your queries through the appropriate channels to ensure a rapid response If you are a reseller please contact your direct contact person or contact...

Page 6: ...the fire alarm control panel to generate audible and or visual alarms if smoke or flames are detected in the field of view At the same time the FireCatcher Camera can be connected via the LAN to a Vi...

Page 7: ...ust zoom 7 Heater Maintains unit temperature 8 Camera unit Contains all camera electronics 9 Cable gasket M20 x2 IP 67 entry for the power alarm cable and Ethernet cable 10 Ethernet connector Connect...

Page 8: ...board power RS485 connector This connector is linked to the housing power output and to the camera serial communications and power input Do not use or modify this connection Status LED behavior Status...

Page 9: ...g use and maintenance recommends a battery standby capacity of 24 hours for continuously monitored systems and 72 hours for non continuously monitored systems BS 5839 1 2017 Fire detection and fire al...

Page 10: ...e length of copper wire at an ambient temperature of 20 C to these values Wire conductor gauge 0 75 mm 18 AWG 1 mm 17 AWG 1 5 mm 16 AWG Maximum cable length Ah 100 m 140 m 210 m Camera positioning SIT...

Page 11: ...alse triggers Avoid sources of dust damp or smoke e g from operating machines in the field of view during normal operation These could lead to recurring false detections Outdoor Outdoor conditions are...

Page 12: ...the field of view the higher the sensitivity and the further away from the camera the lower the sensitivity The minimum required coverage for smoke to be detected depends on the smoke alarm minimum co...

Page 13: ...on the nature of the space Information Axis provides a lens calculator tool on their website that assists in determining the field of view based on lens type and focal length mounting height and dista...

Page 14: ...eps below to install the FireCatcher Camera 1 Mount the bracket Fix the wall mount bracket against the wall by means of 4 screws and wall plugs leading the power outputs cable and the Ethernet cable t...

Page 15: ...ugh this box as illustrated below The FireCatcher Camera is then further mounted on top of the conduit back box as described in the case with wall feed cabling The conduit box can be purchased from yo...

Page 16: ...amera body mounting CAMERA BODY MOUNTING INSTRUCTIONS 1 Open the camera body Open the FireCatcher Camera by removing 4 Torx screws from the bottom 2 Open cable sealing Pull the two tabs from cable gas...

Page 17: ...cable gaskets into the camera Use the RJ45 cap as indicated if you need to enter the Ethernet cable with connector pre attached Make sure the cables are properly fitted through the gasket to avoid in...

Page 18: ...Version 20220420 18 4 Connect Ethernet Insert the Ethernet cable in the corresponding RJ45 Ethernet connector on the back of the camera unit...

Page 19: ...ector of the interface board Consult the connection diagram on the left for identification Connector labels correspond to outputs as follows ALM Output 1 default configuration alarm configurable Norma...

Page 20: ...cene before fixing it to the bracket Fix the bracket using Torx T30 bit Attention Pay attention not to apply excessive force Do not use any automatic gear in order to avoid damaging it by excessive fo...

Page 21: ...the zoom lock screw after adjusting Unlock the focus lock screw and adjust focus ring for best image Do not forget to tighten the focus lock screw after adjusting Focus can be fine tuned in the camera...

Page 22: ...22 8 Mount the camera cover remove protective film Reassemble the camera by attaching the cover with the 4 Torx screws Pay attention not to squeeze the cables Remove the adhesive protective film from...

Page 23: ...n program and follow the instructions on screen 2 Make sure your FireCatcher Camera is powered up and connected to the network Start Axis Device Manager on a Microsoft Windows computer that is on the...

Page 24: ...4 5 Click Finish in the next window to finalize adding the device 6 The new FireCatcher Camera now appears in the Axis Device Manager Client To change the IP address right click the camera and select...

Page 25: ...indicates there is a newer firmware available The FireCatcher Camera analytics have been developed and tested on the firmware that is installed already on the camera Installing other firmware may affe...

Page 26: ...st the focus manually first as described in Installation instructions before fine tuning the focus To adjust the focus of the lens follow these steps 1 Open a browser and log into the camera web inter...

Page 27: ...Version 20220420 27 6 Click fine tune The focus will be optimized for the selected area 7 Click Close to close the focus dialog 6...

Reviews: