![AR 10046836 Operating And Service Manual Download Page 39](http://html1.mh-extra.com/html/ar/10046836/10046836_operating-and-service-manual_2962294039.webp)
Model 500W1000C
Rev A
19
2.6.6.4
Mode Select
This command sets the ALC mode of the amplifier.
Syntax:
MODE:x
Parameters:
Mode(x):
MANUAL
= Set to Manual mode
PULSE
= Set to Pulse mode*
ALC<space>INT
= Set to ALC Internal mode
ALC<space>EXT
= Set to ALC External mode*
Response Format: None (No query for this command)
Example:
To set the ALC mode to Manual mode, send the following command:
MODE:MANUAL<LF>
*Not available on all amplifier models
2.6.6.5
Level Adjust
This command sets the RF Gain, ALC Detector Gain, ALC Threshold, and ALC Response Time.
Syntax:
LEVEL:xy
Parameters:
Parameter(x):
GAIN
= RF Gain
DET
= ALC Detector Gain
THR
= ALC Threshold
RESP
= ALC Response Time
Value(y):
For RF Gain, ALC Detector Gain, and ALC Threshold:
0
= Minimum
100
= Maximum
For ALC Response Time:
0
= Minimum
7
= Maximum
Response Time Setting
Time (mS)
0
1
1
5
2
10
3
30
4
100
5
1000
6
3000
7
3000
Response Format: None (No query for this command)