ACT 2009
- 8 -
Following the informational screens is the ability to change menu options. In
order to change settings, bring up the option and press the right arrow until a small “p”
appears in the lower right corner of the LCD. The user is then able to change the settings
using the specified arrows for each setting.
P
ASSWORD
(enables password protection of settings)
N
ONE
– No password required to change settings
S
ETUP
- Press the enter button and input up to an 8 digit (0-9) password, press the
enter button to confirm new password.
If the password is forgotten the user can perform a master reset by powering the
unit on while holding the left and right arrows (this will reset all settings to the
factory default settings).
D
EFAULT
:
None
M
ANUAL
O
VER
-
RIDE
(turns on fill solenoid for specified time, for testing purposes)
Manual Over-ride can be set from 5 seconds to 99 seconds. (use up and down
arrows to change) To activate this option hold the left and right arrows for
3 seconds.
D
EFAULT
:
10 seconds
D
ELAY TO
S
HUTOFF
(time solenoid valve will stay on after sensor begins sensing water)
Delay to Shutoff can be set from 2 seconds to 5 minutes. (use up and down arrows
to change)
D
EFAULT
:
0:02 seconds
M
AXIMUM
O
N
T
IME
(maximum time solenoid valve is allowed to stay on per fill cycle)
Maximum On Time can be set from 30 minutes to 240 minutes using the up and
down arrow buttons, or continuous using the left and right arrow buttons.
D
EFAULT
:
120 minutes
A
LTERNATE
S
ENSOR
(enables alternate level feature option)
On or Off (use left and right arrows to change)
D
EFAULT
:
Off
D
ELAY TO
N
ORMAL
(time before solenoid is turned on after switching from alternate level
sensing to normal level sensing)
Delay to Normal can be set from 1 minute to 60 minutes. (use up and down
arrows to change)
D
EFAULT
:
60:00 minutes
H
IGH
L
EVEL
O
PTION
(enables high level feature option)
No or Yes (use left and right arrows to change)
D
EFAULT
:
No