AquatiControl Technology ELC-810 Series Operation And Maintenance Manual Download Page 3

 

ACT 2009 

- 3 -

INTRODUCTION

 

 
 

The AquatiControl Technology (ACT) Model ELC-810 is designed to provide the 

most accurate and reliable automatic water level control for swimming pools, spas, 
fountains, and spray pads. All of the user-friendly features incorporated into the system 
were designed with the operator in mind. 
 
 

The importance of precise control of water level in relation to proper filtration and 

water chemistry makes it possible to appreciate a device that will maintain levels within 
+/- 1/8 of an inch.  Installing the system requires basic tools and is accomplished quickly.  
Installation and operating directions can be found on the following pages of this manual.   
 
 

The ELC-810 should ship with the following contents: 

 
 (1) 

Control 

unit 

  Sensing 

Unit(s) 

Standard Well 
Sight Glass 
Wet Well 
Surge Tank 
Deck Well 

 (1) 

Mounting 

Hardware 

 

(1) 

Operation and Maintenance Manual 

 (1) 

Warranty 

Card 

 
 

If any items are not found in this package, please call your closest distributor or 

the factory at (877) 755-8817. 

 

ELC-810-SW  ELC-810-DW   ELC-810-SG  ELC-810-WW   ELC-810-ST 

Standard Well 

 

Deck Well 

 

Sight Glass 

 

Wet Well 

 

Surge Tank 

Sensing unit 

 

Sensing well 

 

Sensing box 

 

Sensing stick 

 

Sensing stick 

5' of ½” 

Polytubing 

 Sensing 

box  

Mounting 

hardware 

 

1 compression 

fitting 

 

2- 1" Clic 

clamps 

1/2" PVC ball 

valve 

 

Mounting 

hardware 

 

25' remote 

cable 

 

Mounting 

hardware 

 

Mounting 
hardware 

2- 1/2" Parker 

fittings 

 

25' remote 

cable 

 

 

25' remote 

cable 

 

25' remote 

cable 

1/2"xclose 

Nipple TBE 

 

 

 

 

 

 

Mounting 
hardware 

 

 

 

 

 

 

 

 

25' remote 

cable 

 

 

 

 

 

 

 

Summary of Contents for ELC-810 Series

Page 1: ...810 AUTOMATIC WATER LEVEL CONTROLLER AquatiControl Technology 3820 South Federal Blvd Sheridan Colorado 80110 Toll Free 877 755 8817 Fax 303 761 1499 www aquaticontrol com Serial No __________________...

Page 2: ...ACT 2009 2 TABLE OF CONTENTS Introduction 3 Installation 4 5 Wiring Diagram 6 Operation 7 9 Routine Maintenance 10 Troubleshooting 11 12 Warranty 13...

Page 3: ...following pages of this manual The ELC 810 should ship with the following contents 1 Control unit Sensing Unit s Standard Well Sight Glass Wet Well Surge Tank Deck Well 1 Mounting Hardware 1 Operation...

Page 4: ...l water level should sit approximately 1 5 up from the bottom of the end cap The surge tank sensing unit is installed in the surge tank at normal operating water level with the included clic connector...

Page 5: ...In order to setup the use of an alternate level on the ELC 810 a second sensing application should be placed at the chosen lower water level and a flow switch supplied with the ELC 810 needs to be in...

Page 6: ...ACT 2009 6...

Page 7: ...arrows The enter button will bring you back to the startup screen Options can be changed by following the directions below The first six screens as you scroll down through the menu are for informatio...

Page 8: ...seconds to 99 seconds use up and down arrows to change To activate this option hold the left and right arrows for 3 seconds DEFAULT 10 seconds DELAY TO SHUTOFF time solenoid valve will stay on after s...

Page 9: ...ally closed flow switches Open or Closed use left and right arrows to change DEFAULT Closed SENSOR TYPE set to Other DEFAULT Other SOUNDER WITH ALARM beeping will occur when in alarm mode if yes is se...

Page 10: ...RGE TANK The Surge Tank Sensing Unit will not normally need to be cleaned however if the cap on the bottom of the sensing application becomes clogged with debris it can be unscrewed and rinsed until c...

Page 11: ...ective sensor Replace sensor Sensing unit not set properly Readjust sensor to water level Wiring is incorrect in sensor junction box Check wiring connection Level light does not come on Cable in ELC 8...

Page 12: ...ACT 2009 12 SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Can t change settings Forgotten wrong password Reset ELC by turning the power on while holding the left and right arrows...

Page 13: ...or part which is returned transportation prepaid to the factory within one year of delivery to the original purchaser and which is proven defective upon examination ACT disclaims all liability for da...