3. Working Principles & Technical Specifications

AQUATIC WATER PUMP Model #                         

SBIC – Submersible Built in Pressure Control

AQSUB-SBIC1000   AQSUB-SBIC1200

Power  INPUT –   ( P1 )          

INPUT Power Draw    

1000 W / 1.3 HP       

1200 W / 1.6 HP             

Power  OUTPUT – ( P2 )

OUTPUT Power Draw

650 W / 0.87 HP

750 W / 1.0 HP

Maximum Flow per Hour

Litres per Hour

6000                 

6300                                           

Maximum Flow per Min.

Litres per Minute

100 l/pm                   

105 l/pm  

Maximum Head

Max Head

34 m/h  

44 m/h  

Max Submersible Depth

Meters

10

10

Outlet feed from Pump 
Body

Inches & mm

G1.5”- 40 mm

G1.5”- 40 mm

Insulation Protection Grade

Insulation Grade

IP-X8

IP-X8

Impellers per Pump

How many per Pump

3 Pieces - NORYL®

4 Pieces - NORYL®

Pressure Control Switch

Float or AUTO

Built in - AUTO

Built in - AUTO

Nett Weight

Kilograms - kg

9

9.3

Gross Weight

Kilograms - kg

10.3

10.6

4. Accessories in the Box with Pump

Outlet Hose Connector with Rubber Washer: 1 Piece.
Operations Manual: 1 Piece.

1 x short roll of TEFLON TAPE

5. Use and Destination of the Pump 

•  Your Pump is designed for Domestic Home use ONLY. 

Your Pump must not be used in following situations : 

•   The Water Temperature to be sucked into the Pump will be above 0° Degrees Celsius ( Freezing ) & 

BELOW a MAXIMUM of 40° Degrees Celsius above Freezing. 

•  Cannot be used continuously 24-7-365 (i.e: like a Fountain Pump, major Irrigation, Commercial use,) 
•   Best used only for Toilets or Laundry / Washing machines, Gardens, Pool top up etc.
•   Corrosive - acids etc, easily combustible, aggressive or explosive liquids (such as gasoline, petroleum or 

nitro thinner), saltwater, oils and greasy grime 

MUST NOT be Pumped - if so WARRANTY will be VOID

.

•   Permanent MAXIMUM Suction Depth is 10 Meters.  

This IS NOT A BORE PUMP.

6. Care & Maintenance

DANGER

Unplug the pump from power point before any work or maintenance

Summary of Contents for AQSUB-SBIC1000

Page 1: ...gent Automatic with Built In Pressure Controller FOR CLEAN WATER ONLY 1000 Watt 1200 Watt These Instructions Suggestions Advice are for your Safety Please Read carefully before Use and keep them Safe for Recall For Model Numbers AQSUB SBIC1000 INOX MULTI AUTO 1000 W 1 0 kW AQSUB SBIC1200 INOX MULTI AUTO 1200 W 1 2 kW 1 10 18 ...

Page 2: ...SAFETY D PERSONAL SAFETY 2 GETTING STARTED 3 WORKING PRINCIPLES TECHNICAL SPECIFICATIONS 4 ACCESSORIES 5 USE AND DESTINATION OF THE PUMP 6 CARE MAINTENANCE 7 TROUBLESHOOTING 8 CERTIFICATE OF CONFORMITY 9 GUARANTEE Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 5 Page 5 Page 5 Page 5 Page 6 Page 7 Page 8 October 2018 ...

Page 3: ...in use C ELECTRIC SAFETY The pump cable plug must match the socket Never modify the plug in any way DO NOT use any adapter plugs Unmodified plugs and matching sockets will reduce risk of electric shock Avoid body contact with earthed or grounded surfaces DO NOT abuse the power cord Never use the cord for carrying pulling or unplugging the pump Keep cord away from heat oil sharp edges or moving par...

Page 4: ...c The Pump must be installed on a flat and solid surface It is BEST PRACTICE to place several pavers on the floor of your Tank to sit the Pump upon so as any sediment is not easily picked up off the floor of your Tank Any sediment picked up could harm the pump and will certainly send dirty water up the line and affect activities such as clothes washing etc If Drinking be sure to have a UV Water Fi...

Page 5: ...0 3 10 6 4 Accessories in the Box with Pump Outlet Hose Connector with Rubber Washer 1 Piece Operations Manual 1 Piece 1 x short roll of TEFLON TAPE 5 Use and Destination of the Pump Your Pump is designed for Domestic Home use ONLY Your Pump must not be used in following situations The Water Temperature to be sucked into the Pump will be above 0 Degrees Celsius Freezing BELOW a MAXIMUM of 40 Degre...

Page 6: ... lower it gently into position 7 Troubleshooting Trouble Problem Please Check Inspect What you should do The Pump DOES NOT Start and DOES NOT make any Movement or Noise Is the Pump plugged in Does the pump start when it is Fully Submerged Plug in the Pump into the 240 Volt Power Point Is the Power Point switched on Check your Electrical Connection Installation The Pump is Running but DOES NOT Deli...

Page 7: ...d verify check valve if applicable Connect a pipe with a suitable diameter and suppress reduction of the water passage 8 Certificate of Conformity AQUATECH AUSTRALASIA Pty Ltd AQUATICA Water Pumps Declares that following pumps AQSUB SBIC1000 INOX MULTI AQSUB SBIC1200 INOX MULTI Are manufactured under strict Agreement and Quality Control in The P R C and Comply with the following directives Directi...

Page 8: ... of slurry sludge stones sand salt water water with high lime or an acid content etc 7 Lack of Maintenance or Cleaning of the Stainless Steel Filter Gauze Front at bottom of Pump Parts NOT covered by the Warranty if these parts are supplied with the Pump Suspension Stainless Steel Wire Nylon Rope External Fittings A Repair which results in an Exchange with NEW product during the Warranty period DO...