background image

3

1. Security Instructions for Your Safety and the Best Use of Your Pump

PLEASE READ THE FOLLOWING INSTRUCTIONS

A. SAFETY

•  Unplug the Water Pump from the mains power outlet before any intervention, service, inspection etc.
•  When the Pump is running, there must be no particles in the water ( This Pump is for Clean Water 

use ONLY ). 

•  DO NOT

 use the Pump without an 

Electrical CIRCUIT BREAKER.

•  The pump must be used with 230V AC Power supply, as indicated on the rating plate. 
•  DO NOT use the power cable for carrying the pump or for unplugging. 
•  Make sure that electric connections are protected from humidity. 
•  Avoid dry-running of the pump. Never use the pump if suction hose is obstructed. 
•  It is strictly forbidden to pump corrosive, easily combustible, aggressive or explosive liquids (such as 

petroleum or nitro thinner), saltwater and food. 

•  The temperature of the liquid must not 40°C. 

DO NOT use the pump if safety devices are damaged or depleted. Never deactivate safety devices. 

B. PUMP ENVIRONMENT 

DO NOT operate pumps in explosive atmospheres, such as in the presence of flammable liquids, gases. 
Keep children and unqualified persons away from the pump when it is in use. 

C. ELECTRIC SAFETY 

•  The pump cable plug must match the socket. Never modify the plug in any way. DO NOT use any 

adapter plugs. Unmodified plugs and matching sockets will reduce risk of electric shock. 

•  Avoid body contact with earthed or grounded surfaces.
•  DO NOT abuse the power cord. Never use the cord for carrying, pulling or unplugging the pump. 

Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase 
the risk of electric shock. 

•  When operating a pump outdoors, use an extension cord suitable for outdoor use. Use of a cord 

suitable for outdoor use reduces the risk of electric shock. 

•  The pump is equipped with a 3-pin plug at the end of the power lead & is compatible for AUSTRALIA. 

The power source in AUSTRALIA complies with International Regulations. 

•   If supplied power cord is damaged, it must be replaced by the manufacturer under warranty, our 

service agent or similarly qualified persons as appointed by Aquatica Water Pumps. 

D. PERSONAL SAFETY 

•  Risk of injury due to hot water

: If the pump runs for an extended period when the outlet is closed, the 

water in the pump can become heated which can then emerge from the outlet and cause injuries. 

•   Stay alert, watch what you are doing and use common sense when operating the pump. 
•   Maintain your pump. If the pump is damaged, ensure it is repaired by a specialist before any use. 

Summary of Contents for AQSUB-SBIC1000

Page 1: ...gent Automatic with Built In Pressure Controller FOR CLEAN WATER ONLY 1000 Watt 1200 Watt These Instructions Suggestions Advice are for your Safety Please Read carefully before Use and keep them Safe for Recall For Model Numbers AQSUB SBIC1000 INOX MULTI AUTO 1000 W 1 0 kW AQSUB SBIC1200 INOX MULTI AUTO 1200 W 1 2 kW 1 10 18 ...

Page 2: ...SAFETY D PERSONAL SAFETY 2 GETTING STARTED 3 WORKING PRINCIPLES TECHNICAL SPECIFICATIONS 4 ACCESSORIES 5 USE AND DESTINATION OF THE PUMP 6 CARE MAINTENANCE 7 TROUBLESHOOTING 8 CERTIFICATE OF CONFORMITY 9 GUARANTEE Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 5 Page 5 Page 5 Page 5 Page 6 Page 7 Page 8 October 2018 ...

Page 3: ...in use C ELECTRIC SAFETY The pump cable plug must match the socket Never modify the plug in any way DO NOT use any adapter plugs Unmodified plugs and matching sockets will reduce risk of electric shock Avoid body contact with earthed or grounded surfaces DO NOT abuse the power cord Never use the cord for carrying pulling or unplugging the pump Keep cord away from heat oil sharp edges or moving par...

Page 4: ...c The Pump must be installed on a flat and solid surface It is BEST PRACTICE to place several pavers on the floor of your Tank to sit the Pump upon so as any sediment is not easily picked up off the floor of your Tank Any sediment picked up could harm the pump and will certainly send dirty water up the line and affect activities such as clothes washing etc If Drinking be sure to have a UV Water Fi...

Page 5: ...0 3 10 6 4 Accessories in the Box with Pump Outlet Hose Connector with Rubber Washer 1 Piece Operations Manual 1 Piece 1 x short roll of TEFLON TAPE 5 Use and Destination of the Pump Your Pump is designed for Domestic Home use ONLY Your Pump must not be used in following situations The Water Temperature to be sucked into the Pump will be above 0 Degrees Celsius Freezing BELOW a MAXIMUM of 40 Degre...

Page 6: ... lower it gently into position 7 Troubleshooting Trouble Problem Please Check Inspect What you should do The Pump DOES NOT Start and DOES NOT make any Movement or Noise Is the Pump plugged in Does the pump start when it is Fully Submerged Plug in the Pump into the 240 Volt Power Point Is the Power Point switched on Check your Electrical Connection Installation The Pump is Running but DOES NOT Deli...

Page 7: ...d verify check valve if applicable Connect a pipe with a suitable diameter and suppress reduction of the water passage 8 Certificate of Conformity AQUATECH AUSTRALASIA Pty Ltd AQUATICA Water Pumps Declares that following pumps AQSUB SBIC1000 INOX MULTI AQSUB SBIC1200 INOX MULTI Are manufactured under strict Agreement and Quality Control in The P R C and Comply with the following directives Directi...

Page 8: ... of slurry sludge stones sand salt water water with high lime or an acid content etc 7 Lack of Maintenance or Cleaning of the Stainless Steel Filter Gauze Front at bottom of Pump Parts NOT covered by the Warranty if these parts are supplied with the Pump Suspension Stainless Steel Wire Nylon Rope External Fittings A Repair which results in an Exchange with NEW product during the Warranty period DO...

Reviews: