11. Funktions
General overview of the cooling circuit
Pool water heating mode:
The cold, liquid coolant absorbs the heat in the air via the evaporator; the evaporation process begins here.
The wet steam is sucked in through the compressor. The pressure and temperature increase further. It is
then passed on to the titanium heat exchanger (condenser). There, the heat is transferred to the pool water
and the coolant lique
fi
es (condensation). Then the liquid coolant is fed back through the expansion capillary
(pressure reduction) to the evaporator where the process starts again from the beginning.
Warm air
Evaporator
Cold air
Pressure gauge
One-way
valve
Expansion
capillary
Warm water
Cold water
Titanium heat exchanger
Compressor