25 |
10. Technical Data
Technical data at
50 Hz
Aqua 4 Fun
60
Aqua 4 Fun
100
Aqua 4 Fun
140
Aqua 4 Fun
160
Aqua 4 Fun
200
Heating capacity at
A19/W26°C [kw]
5.0
8.1
10.5
13.0
16.8
Heating capacity at
A26/W26°C [kW]
6.0
9.0
12.0
15.0
18.0
Heating capacity at
A15/W26°C [kW]
4.25
6.5
9.0
9.5
13.0
Rated power consumption
[A]
5.1
7.2
9.6
11.7
4.4
Power supply [V]
230
230
230
230
230
COP depending on the
operating state [ca. >]
6
6
6
6
6
Electricaly input [kW]
1.04
1.45
1.98
2.45
2.90
Fuse [A]
1 pol. C 16
1 pol. C 16
1 pol. C 16
1 pol. C 20
3 pol. C 16
Connections glued
connection [mm]
Ø 50
Ø 50
Ø 50
Ø 50
Ø 50
Noise level 1/10 m free
fi
eld [db(A)]
38/50
38/52
39/52
39/54
40/56
Acoustic power level 1 m
hemisphere [db(A)]
59
60
60
62
64
Refrigerant R410A/GWP
2088 Co²e(t) [kg]
0.5/1.04
0.8/1.67
1.0/2.08
1.1/2.29
1.6/3.34
Compressor
Rotary
Water throughput rate
[m³/h]
2.3
3.0
4.5
5.3
6
Heat exchanger pressure
loss [kPa]
2.4
3.2
6.0
10
15
Dimensions approx. [mm]
790x330x580 952x360x610 952x360x610 952x360x610 1130x460x860
Weight approx. [kg]
36
50
65
75
98
Pool size with thermal
covering* [m³]
up to 15
up to 30
up to 40
up to 50
up to 60
* All values are based on an air temperature of 26 °C, a pool water temperature of 26 °C (pool covered,
thermal covering).
Utilisation time approx. mid-May to mid-September, with a daily
fi
lter pump running time of 10 to 12 hours.
A special version is required for different conditions of use. Ask your local swimming pool dealer.
Caution
Risk of frost at sub-zero temperatures through water-bearing parts!
Summary of Contents for AQUA 4 Fun 100
Page 51: ...51...