3. 

SERVICING 

3.1 

MAINTENANCE AND CARE OF YOUR EQUIPMENT 

The AquaTech‐Pressmain equipment that is described in this instruction booklet has been manufactured and 
tested to the highest standards of design and quality. It will give trouble free operation over many years provided 
it is maintained regularly from when it is commissioned. To keep it operating efficiently in a safe, economical and 
environmentally friendly condition, regular maintenance is an essential part. 

 

AquaTech‐Pressmain along with its’ service division, Acorn Pressurisation Services are the official providers of 
commissioning and maintenance services. (see below).  
Several companies operating under the Aquatronic Group Management structure are available to fulfil a wide 
range of servicing and maintenance requirements, as detailed below. 

3.2 

LEGAL REQUIREMENTS 

Hydraulic Accumulators/Expansion Vessels installed as part of/in conjunction with this equipment, with Pressure 
x Volume above 250 Bar‐litres, require formal inspection in accordance with a “Written Scheme of Examination”. 
This is a Legal Requirement on the part of the Owner/User under the “Pressure Systems Safety Regulations” 
(PSSR). A “Written Scheme” and regular inspection can be provided by either Acorn Pressurisation Services 
(combined maintenance and inspection) or ESIS Ltd (inspection only), see details below. 

Plant Servicing & Inspection 

ACORN PRESSURISATION SERVICES,  
AGM House, Essex, CO6 1GT. 

 

Ph: 01206 215151 

10 Wheel Forge Way, Manchester. M17 1EH.   Ph: 0161 226 4727 

 

Acorn provides maintenance and installation of all types of packaged water pumping equipment for building services. Its 
specialist fields are Pressure booster equipment and sealed systems for heating and chilled water distribution systems. 
Regular servicing of any plant for essential services is vital because wear and tear are very gradual processes. 
With preventative maintenance, the costs are small and benefits in reliability, safety and economy can be significant. Acorn 
Pressurisation Services can provide a complete package of schemes for preventative maintenance on all AquaTech‐Pressmain 
and other makes of equipment. 

 

Pressure Vessel Inspection 

ESIS ENGINEERING SAFETY & INSPECTION SERVICES LTD, 
AGM House, London Rd, Copford, Colchester, Essex, CO6 1GT. 
Phone: 01206 215141 

 

Under the Pressure Systems Safety Regulations, expansion vessels and hydraulic accumulators, generally 250 bar‐litres and 
greater, and protection devices, require a Written Scheme of Examination before they can be operated. ESIS Inspection and 
Insurance Services Limited specifications can provide the means to comply with these regulations. These services can be 
extended to cover other units e.g. air pressure receivers etc. 

 

3.3 

SERVICE CONTACTS 

For service during warranty period contact:   AQUATECH‐PRESSMAIN Service Department 

Head Office Tel: 01206 215121  

Manchester Office Tel: 0161 226 4727 

For regular servicing, contact service division:  ACORN PRESSURISATION SERVICES 

Head Office Tel: 01206 215151  

Manchester Office Tel: 0161 226 4727 

who will be pleased to give you expert advice on this or any other servicing matter. 
 
 

4. 

DISPOSAL 

Disposal of this product or parts of it must be carried out in accordance with the following guidelines: 

 

Use the local public or private recycling/waste collection service. 

 

In case such a recycling/waste collection service does not exist or cannot handle the materials used in this 
product, please deliver the product or any hazardous material from it to your nearest AquaTech‐Pressmain 
office. 

 
 
 

Summary of Contents for AquaBreak AB5

Page 1: ...BREAKTANK PUMPSET FOR BACKFLOW PROTECTION TO FLUID CATEGORY 5 ISSUE 3 18 07 2017 Head Office AGM House London Rd Copford Colchester Essex CO6 1GT UK Tel 01206 215121 Email aftersales agm plc co uk Man...

Page 2: ...NANCE 6 1 INSTALLATION INSTRUCTIONS 7 1 1 ADDITIONAL WARNINGS 7 1 2 ADDITIONAL CAUTIONS 7 1 3 PROCEDURE 7 1 3 1 OFF LOADING AT SITE 7 1 3 2 LOCATION 8 1 3 3 FIXING 8 1 3 4 PIPEWORK 9 1 3 5 FLOW THROUG...

Page 3: ...ions PSSR and the Owner User should be made aware of their responsibility for this see section 3 Servicing Failure to install operate use maintain the equipment as recommended below could cause damage...

Page 4: ...it will contain under worst case fault conditions E g fully saturated pressure vessel with no air charge break tank full to overflowing etc Failure to observe this could cause serious mechanical dama...

Page 5: ...accumulators 0 2 15 It is the installers responsibility to ensure subsequent pipework etc can accept the pressures generated by the equipment pumpset and to install an overpressure safety device into...

Page 6: ...nning causing pump seal damage and water leakage 0 3 8 Do no attempt to start pumps without liquid in volutes pumps must be fully primed see 1 2 2 mechanical seals must have a film of liquid between f...

Page 7: ...pplied as loose item is installed in the breaktank overflow warning pipe see fig 1 3 1 2 4 Mains water pressure to unit should be between 1 0 and 3 0Bar Ensure a pressure reducing valve set at a maxim...

Page 8: ...a minimum distance of 500mm all round There must be sufficient room to fully open panel door lift and withdraw pumps withdraw diaphragms from vessels Any Hydraulic Accumulator supplied should be loca...

Page 9: ...it an extra non return valve to the discharge as it may interfere with the correct operation of the non return valve already fitted as standard in the pumpset 1 3 4 5 Connect site pipework to mains wa...

Page 10: ...ure to the correct level see section 2 4 dependent on the application required for the vessel Refer to the Operating parameters at the back of this manual or contact Aquatech Pressmain for advice 1 3...

Page 11: ...eak Tank Stop Start Filling Solenoid Probes B3 B2 B1 B2 B3 B1 Level Control Relay set to FS filling short delay medium sensitivity 75k range 5k 150k Solenoid Valve n c min com max SV1 LR1 A1 A1 14 14...

Page 12: ...authorised AquaTech Pressmain agent This Assurance does not apply to those items not supplied by us or to defects arising from parts not made or approved by AquaTech Pressmain The individual manufactu...

Page 13: ...ss of all mechanical and electrical connections to ensure they have not loosened during transit 2 2 5 with the pumpset switched off IS1 and the motor circuit breaker switched off CB1 close the dischar...

Page 14: ...all or floor mounted 2 3 3 1 For normal operation all pumpset inlet and discharge valves should be left open all hydraulic accumulator expansion vessel isolating valves should be left open and drain c...

Page 15: ...onds and switch power on again to reset control relay No water pump does run Pump air locked Vent prime pump to remove all air Check pump suction strainer inlet filter Reduced intermittent flow Pump p...

Page 16: ...any build up of debris Fig 2 1 Pump inlet filter suction strainer Mains water inlet strainer The mains water inlet strainer should be regularly checked to remove any build up of debris Fig 2 2 Mains w...

Page 17: ...s Its specialist fields are Pressure booster equipment and sealed systems for heating and chilled water distribution systems Regular servicing of any plant for essential services is vital because wear...

Page 18: ...ter Essex CO6 1GT UK Telephone 01206 215121 OPERATING PARAMETERS SERIAL No MODEL AB5 THE SERIAL MODEL NUMBERS MUST BE QUOTED WHEN REQUESTING ASSISTANCE ELECTRICAL DATA Supply 230 volts 1 Ph 50 Hz Full...

Reviews: