AquaStar 125B LPS Installation And Operating Instructions Manual Download Page 8

8

FOR YOUR SAFETY READ BEFORE
LIGHTING THE PILOT

Warning: If you do not follow these instructions exactly, a
fire or explosion may result causing property damage,
personal injury or loss of life

A. This appliance  has a piezo-igniter  for lighting the pilot
burner. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch; do not use any phone

in your building

- Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

- If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to push in or turn the gas control
buttons. Never use tools. If a button will not push in, check
to make sure the buttons are being pushed in the proper
sequence. Follow these instructions exactly. If control
button(s) are jammed, close the gas supply and call a
qualified service technician. Attempted forceful repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control
system and any gas control which has been under water.

Fig. 5 - Water valve and “S” water con-

nectors,  top view

Connecting the pressure relief valve (PRV)

A listed pressure relief valve supplied with the heater must
be installed at the time of installation. No valve is to be
placed between the PRV and the heater. No reducing
coupling or other restriction may be installed in the
discharge line. The discharge line must be installed such
that it allows complete drainage of both the PRV and the
line. The location of the PRV must be readily accessible
for servicing or replacement., and be mounted as close to
the water heater as possible. See Fig 6. To install the PRV,
a suitable fitting connected to an extension on a “T” fitting
can be sweated to the hot water line.

OPERATING INSTRUCTIONS

Before proceeding with the operation of the heater make
sure that the system is filled with water.
Make sure the water heater drain plug is closed. See Figure
7 below.

Fig. 7 - Water heater drain plug

Fig. 6 - Pressure Relief Valve

Open the cold water inlet supply to the heater fully.
Open a hot water faucet to permit the water to fill the heater
and the piping and to eliminate the air trapped in the system
Close the hot water faucet after the water flows freely and
all the air has escaped from the system.  The water heater
is now ready to work.

For installation on a private well system, be sure that the
water pressure is set between 30 and 50 psi.

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information above on this plate.
2. The gas valve must be turned off by depressing the

gas valve off button (     ).

3. Wait five (5) minutes to clear out any gas. If you smell

gas, STOP! Follow “B” in the safety information above
on this plate. If you don’t smell gas, go to the next step.

4. The pilot burner is located behind the peephole in the

front center of the jacket directly below this instruction
plate.

5. Depress PILOT button (    ) and light pilot by pushing

PILOT INGITER button (    ).  This may have to be
repeated.

6. Observe the pilot flame through the peephole. The pilot

button (      ) should be held down at least 10 seconds
with pilot burning.  When the pilot button is released the
pilot should continue to burn.

- If the gas valve button does not pop up when released,

stop and immediately call your service technician or gas
supplier.

- If pilot does not stay lit, repeat steps 1 through 6.
- If pilot will not stay lit after several tries, depress the

OFF button (     ), and call your service technician or gas
supplier.

7. When lit, depress the ON button (        ). The heater will

now fire when water is drawn at a rate greater than the
threshold flow rate.

Summary of Contents for 125B LPS

Page 1: ...pliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phon...

Page 2: ...gy efficiency Automatic Thermostatic Control for steady hot water temperature Input BTU s modulate to zero to prevent overheating of water from pre heat source Safety thermocouple at pilot burner Auto...

Page 3: ...S FROM COMBUSTIBLE AND NON COMBUSTIBLE MATERIALS FOR ALCOVE INSTALLATIONS FRONT VIEW SIDE VIEW AQUASTAR MODELS 125B 125BL 125BS 125X MODEL 125B 125B LOW PRESSURE 125B SOLAR 125X TOP A 12 FRONT B OPEN...

Page 4: ...anada The Installation should conform with CGA B149 1 2 INSTALLATION CODES and or local installation codes 2 Carefully plan where you install the heater Correct combustion air supply and flue pipe ins...

Page 5: ...the building 2000 Btu hr if all air is taken from the outside by horizontal ducts 4000 Btu hr if all air is taken from the outside by direct openings or vertical ducts Louvers grills and screens have...

Page 6: ...vent pipe connectors require a 6 inch clearance from combustibles National Fuel Gas Code specifies double wall Type B vent pipe be used in cold climates and for gas vents running through attics We co...

Page 7: ...ency malfunction of the supply system the gas valve and regulator must be checked for safe operation Make sure that the regulator vent is protected against blockage Vent blockage could occur during ic...

Page 8: ...adily accessible for servicing or replacement and be mounted as close to the water heater as possible See Fig 6 To install the PRV a suitable fitting connected to an extension on a T fitting can be sw...

Page 9: ...me and should resemble the diagram in Fig 8 If the flame is yellow or if the pilot knob has to remain depressed for a long time in order to keep the pilot lighted the pilot burner and or the pilot bur...

Page 10: ...coils should be flushed with a descaling solution Consult your dealer or Controlled Energy for instructions pulled off washed and blown out The pilot orifice has likewise to be cleaned or exchanged C...

Page 11: ...er valve assembly components need to be replaced immediately Note Water valve for model 125B S is part 8707002380 for both LP and NG models Contact service person to clean water valve or replace if co...

Page 12: ...at the tap the lower hot water pressure may be overpowered by a much higher cold water pressure which may cause the Aquastar burners to shut down Make sure faucet aerators or shower heads are free of...

Page 13: ...7 9 1 Heat exchanger 2 Pilot assembly 3 Burner manifold gas pressure test nipple 4 Main gas burner 5 Pilot gas tubing 6 Gas valve 7 Piezo igniter 8 Location of pressure tap screw 9 Water valve 10 Gas...

Page 14: ...14 AQ 125 BS Fig 11 INTERIOR COMPONENTS DIAGRAM AND PARTS LIST...

Page 15: ...lot Tube 8 700 707 316 15 Thermocouple 8 747 202 083 16 Burner assembly washer 8 710 103 060 17 Gas valve LP 8 707 011 467 Gas valve NG 8 707 011 469 18 Gas supply pipe 8 700 705 464 19 Electromagnet...

Page 16: ...ight Minimum Diameter Minimum Height 5 inches 6 feet NOTE Vent size must not be restricted Installation must comply with national fuel gas code venting requirements for a 117 000 Btu Category I applia...