AquaForce PRO

®

 Pump Specs

Model Number

4000-8000

Average Pond Size Recommendation

For ponds up to 16,000 gallons

Maximum Flow Rate

7,794 GPH

Maximum Head Height

28 ft

Motor Type

Asynchronous

Wattage

500-660*

Amperage

5.5

Power Cord Length

20 ft

Pump Discharge Diameter

1.5” MPT

Multi-Hose Fitting Diameters

1”, 1.25”, 1.5”, 2”

Warranty

3-Year Limited

Typical Installation in an 

ecosystem water garden

•  The AquaForce

®

 Pump is designed to 

be submerged directly into the pond. 
To maximize pond circulation, locate 
the AquaForce

®

 pump as far away as 

possible from the location of the water 
entering back into the water feature.

•  It is recommended that the pump NOT 

be positioned in the deepest area of 
the pond. This will protect the fish by 
preventing the pond from completely draining in the case 
of a leak in the plumbing or filter. Bricks or stones can be 
used, if needed, to raise the pump up off the bottom of the 
pond.

4

5

 

US 1-866-877-6637 | 

 

CAN 1-866-766-3426 | www.aquascapeinc.com

www.aquascapeinc.com | 

☎ 

CAN 1-866-766-3426 | 

☎ 

US 1-866-877-6637

Installation

•  Always operate the pump fully submerged. Failure to  

do so will overheat the pump and cause it to fail, thus 
voiding the warranty. DO NOT OPERATE DRY.

•  Use only in fully assembled state, and be sure that both 

the upper and lower cage screens are completely snapped 
together.  Failure to operate the pump without the filter 
cage closed will allow large debris to enter the pump, 
causing the pump to fail and voiding the warranty.

•  DO NOT wear loose clothing that may become  

entangled in the impeller or other moving parts. 

•  Keep clear of suction and discharge openings.  

DO NOT insert fingers into pump with power connected.

•  DO NOT pump hazardous materials or liquids,  

such as oil, saltwater or organic solvents.

•  DO NOT block or restrict discharge.

•  Products returned must be cleaned, sanitized, or 

decontaminated as necessary prior to shipment. 
This will ensure that employees will not be exposed 
to health hazards in handling said material. All 
applicable laws and regulations shall apply.

IMPORTANT:

 Aquascape, Inc. is not responsible 

for losses, injury, or death resulting from a failure 
to observe these safety precautions, or misuse/
abuse of filters, pumps or other equipment.

AquaForce

®

 PRO Specifications

• Input Voltage: 120V AC
• Input Frequency: 60 Hz
• Submersible pump
• For outdoor or indoor use
• Thermally protected
• This pump has been evaluated for use with freshwater only
• Input Amps & Wattage: 

See chart on next page

•  The AquaForce

®

 includes a wide assortment of fittings to 

choose from. Select the appropriate fitting(s) needed for  
your application. 

•  The threaded collar, on all of the fittings, enables the 

AquaForce

®

 pump to be installed and removed without the 

need for any tools. Do not use tools to attach the fittings onto 
the pump discharge. Fittings need to be hand-tightened only.

 

•  The extremely versatile rotational ball outlet provides you 

with the ability to adjust the pump discharge to the perfect 
position required by your water feature. Loosening the 
threaded collar allows you to rotate the upper half of the 
ball.  A flat rubber washer seal is included to ensure a hand-
tight and leak-free connection. Make sure the flat rubber 
washer is in place before installing the fittings.

*Wattage range depending on remote-control flow setting

•  It is recommended to mount the receiver above the ground 

on a post, fence or wall. 

•  Plug the pump into the receiver making sure that blue plug 

gasket is in plug port. 

•  Plug the Receiver into an external GFI-rated electrical 

source. Once the pump is running and water is circulating, 
check for any leaks where the external connections are 
made.

Using the AquaForce

®

  

as a Winter Bubbler

•   The  AquaForce

®

 can also be used to prevent winter fish 

loss by keeping a hole open in the ice during the cold 
winter months. The AquaForce

®

 helps ensure there is 

•  Select the Multi-Hose 

fitting that best fits your 
new or current tubing/
hose. 

•  In some instances the tubing/hose may be tight and 

difficult to use with hose fitting barbs. If this is the case, 
we recommend heating the hose with the use of a hair 
dryer or simply dipping the hose in very hot water for a few 
seconds. Lubrication can also be used; we recommend 
silicone grease or olive oil. We recommend putting the 
fitting on the filter before attaching the tubing/hose. Once 
the fitting is in place, attach the tubing/hose onto the fitting 
with a twisting motion, pushing it into place.

•  Attach tubing to the fitting.  If 

tubing is loose on fitting, use 
a hose clamp (not included) to 
secure tubing onto the fitting.

•  Connect the other end of 

the pump tubing to the pond 
filter, such as a biological 
filter, waterfall spillway or 
pressurized filter.

•  If using pipe with a larger 

diameter than the smaller 
fittings of the Multi-
Hose Adapters, cut off 
the smaller section or 
sections to avoid any flow 
restriction.

Multi-Hose Adapter

Summary of Contents for 91104

Page 1: ...le Flow Pump Remote Controlled Submersible Solids Handling Waterfall Filter Pump For Model 4000 8000 Item 91104 I N S T R U C T I O N S M A I N T E N A N C E Engineered for Continuous Use 3 Y E AR WARRA N T Y G A R A N TIE DE TRO I S A N S 3 ...

Page 2: ...ater will ensure proper gas exchange throughout the winter VISIT OUR WEBSITE DOWNLOAD A FREE COPY OF OUR CATALOG POND SQUAD INSTALLATION INSTRUCTIONS Contact Us For more information about our company or products please visit our website at www aquascapeinc com or call US 1 866 877 6637 CAN 1 866 766 3426 www facebook com AquascapeInc www youtube com aquascape4 www twitter com AquascapeInc www flip...

Page 3: ...door use Thermally protected This pump has been evaluated for use with freshwater only Input Amps Wattage See chart on next page The AquaForce includes a wide assortment of fittings to choose from Select the appropriate fitting s needed for your application The threaded collar on all of the fittings enables the AquaForce pump to be installed and removed without the need for any tools Do not use to...

Page 4: ...his reason Remote Control replacement kits include both Remote Control and Receiver Battery Installation 1 Remove 4 screws and back cover plate 2 Place battery into the battery compartment Requires 1 23A 12V battery 3 Replace back cover and install screws Decrease Flow Increase Flow On Off Internal Pump Cleaning If you have thoroughly cleaned the filter cage screens and still have diminished flow ...

Page 5: ...emote Control Not Working Check to make sure the switch located on the Receiver is in the remote control position See page 6 Check the label on the back of the receiver and transmitter to make sure they are paired to the same frequency Check to make sure the remote control battery is installed properly Replace battery if needed I N S T R U C T I O N S E T E N T R E T I E N 3 Y E AR WARRA N T Y G A...

Page 6: ...book com AquascapeInc www youtube com aquascape4 www twitter com AquascapeInc www flipboard com profile AquascapeInc Rejoignez nous sur Symbole AVERTISSEMENT Vous alertera sur la possibilité de dommages corporels ou matériels si vous ne vous conformez pas aux avertissements qui les accompagnent Le danger peut avoir une origine mécanique ou être dû à une électrocution Symboles utiles Symbole CONSEI...

Page 7: ...ussi loin que possible de l emplacement où l eau entre à nouveau dans l installation aquatique Il est recommandé de NE PAS placer la pompe dans la partie la plus profonde du plan d eau Ceci protégera les poissons en empêchant le plan d eau de se vider complètement en cas de fuite dans la plomberie ou le filtre Des briques ou des pierres peuvent être utilisées si nécessaire pour surélever la pompe ...

Page 8: ...couverture 2 Placez la batterie dans le compartiment de la batterie a besoin 1 23A 12V la batterie 3 Replacez le couverture arrière et installer les vis Cage de pompe N enlevez ni la cage supérieure ni la cage inférieure de la pompe lorsque vous l actionnez Faire fonctionner la pompe sans la cage de filtration ou avec une cage brisée permettrait à des débris de grande taille d entrer dans la pompe...

Page 9: ... n enveloppe la turbine Assurez vous que la pompe reçoit la bonne tension Pompe en panne L interrupteur du disjoncteur de fuite à la terre GFCI peut avoir été déclenché La pompe ne reçoit pas la bonne tension Télécommande ne fonctionne pas Assurez vous que l interrupteur sur le récepteur est en mode télécommande Vérifiez l étiquette sur le dos de l émetteur et le récepteur pour s assurer qu ils so...

Reviews: