background image

8

 

US 1-866-877-6637 | 

 

CAN 1-866-766-3426 | www.aquascapeinc.com

AquaForce

®

 

Adjustable Flow Pump

Pompe de filtrage 

et cascades avec 

télécommandé, 

submersible et 

résistante au 

colmatage

Pour les modèles :

   4000-8000 

(article n

o

 91104)

Conçue pour une  

utilisation continue

Replacing Pump in Cage

•  Replace the pump into the lower cage and secure in  

place with the brackets. Also replace the power cord in  

the strain relief.

•  Reinstall filter cage and close all 5 tabs. 

Winter Storage 

•  The pump can be run during freezing weather if desired 

but should be removed if shutting down the pump for the 

winter.  Disconnect the threaded collar on the discharge 

fitting and remove the pump from the pond (be careful 

not to lose the flat rubber washer). Clean the pump and 

cage screens with fresh water and store the pump in a 

frost-free location.

Troubleshooting

• 

Reduced Water Flow

 

   –  Pump or plumbing may be clogged. It may be necessary 

to clean the pump cage screens and impeller.

•  

Pump Hums and Doesn’t Push Water

  –  Pump or plumbing may be clogged.  It may be 

necessary to clean the pump cage screens and impeller.

  –  Remove the water chamber cover and inspect and clean 

the impeller rotor assembly and internal pump body.

  –  Make sure nothing is blocking or wrapped around the 

impeller.

  –  Make sure the pump is receiving the correct voltage.

• Pump Not Working

   –  The ground-fault circuit-interrupter (GFCI) may  

have tripped.

   –  The pump is not receiving the correct voltage.

• Remote Control Not Working

   –  Check to make sure the switch located on the Receiver 

is in the remote control position. See page 6.

   –  Check the label on the back of the receiver and 

transmitter to make sure they are paired to the  
same frequency. 

   –  Check to make sure the remote control battery is 

installed properly. Replace battery if needed.

I N S T R U C T I O N S   E T   E N T R E T I E N

YE

AR

 WARRAN

TY

G

A

R

A

N

TIE DE TRO

IS

 A

N

S

3

www.aquascapeinc.com

Replacement Parts

3 YEAR WARRANTY

The AquascapePRO AquaForce

®

 Adjustable Flow Pump is guaranteed for three years from date of purchase. 

Proof of purchase required. Warranty does not cover damage resulting from negligent handling, misuse or lack of 

reasonable maintenance or care. Warranty is valid against defects due to material and the company’s workmanship 

only. The sole obligation shall be to replace the defective unit with a suitable replacement unit. Units should be 

checked for proper operation prior to returning as defective. No liability for loss or damage of any nature  

or kind, whether arising out of or from the use of the product, whether defective or not defective, is assumed by 

Aquascape, Inc. or its affiliates.

Warranty

AQUAFORCE PRO

®

 PUMPS  Replacement Parts

Diagram 

Numbers

Item # Product

91075 AquaForce

®

 Replacement Cage Discharge Fitting Kit

 

91077 AquaForce

®

 

 3600/5200 Replacement Water Chamber Cover

91096 AquaForce

®

 4000/8000 (G2) Replacement Pump Cage Kit

91079 AquaForce

®

 (G2) Replacement Cage Clip Kit

91101 AquaForce

® 

PRO Replacement Impeller Kit

45029

AquaSurge

® 

PRO/ AquaForcePRO Pump Remote  

and Receiver Kit (G2)

x 5

3

1

2

5

4

1

2

3

4

1

2

3

4

x 5

3

1

2

5

4

6

6

Summary of Contents for 91104

Page 1: ...le Flow Pump Remote Controlled Submersible Solids Handling Waterfall Filter Pump For Model 4000 8000 Item 91104 I N S T R U C T I O N S M A I N T E N A N C E Engineered for Continuous Use 3 Y E AR WARRA N T Y G A R A N TIE DE TRO I S A N S 3 ...

Page 2: ...ater will ensure proper gas exchange throughout the winter VISIT OUR WEBSITE DOWNLOAD A FREE COPY OF OUR CATALOG POND SQUAD INSTALLATION INSTRUCTIONS Contact Us For more information about our company or products please visit our website at www aquascapeinc com or call US 1 866 877 6637 CAN 1 866 766 3426 www facebook com AquascapeInc www youtube com aquascape4 www twitter com AquascapeInc www flip...

Page 3: ...door use Thermally protected This pump has been evaluated for use with freshwater only Input Amps Wattage See chart on next page The AquaForce includes a wide assortment of fittings to choose from Select the appropriate fitting s needed for your application The threaded collar on all of the fittings enables the AquaForce pump to be installed and removed without the need for any tools Do not use to...

Page 4: ...his reason Remote Control replacement kits include both Remote Control and Receiver Battery Installation 1 Remove 4 screws and back cover plate 2 Place battery into the battery compartment Requires 1 23A 12V battery 3 Replace back cover and install screws Decrease Flow Increase Flow On Off Internal Pump Cleaning If you have thoroughly cleaned the filter cage screens and still have diminished flow ...

Page 5: ...emote Control Not Working Check to make sure the switch located on the Receiver is in the remote control position See page 6 Check the label on the back of the receiver and transmitter to make sure they are paired to the same frequency Check to make sure the remote control battery is installed properly Replace battery if needed I N S T R U C T I O N S E T E N T R E T I E N 3 Y E AR WARRA N T Y G A...

Page 6: ...book com AquascapeInc www youtube com aquascape4 www twitter com AquascapeInc www flipboard com profile AquascapeInc Rejoignez nous sur Symbole AVERTISSEMENT Vous alertera sur la possibilité de dommages corporels ou matériels si vous ne vous conformez pas aux avertissements qui les accompagnent Le danger peut avoir une origine mécanique ou être dû à une électrocution Symboles utiles Symbole CONSEI...

Page 7: ...ussi loin que possible de l emplacement où l eau entre à nouveau dans l installation aquatique Il est recommandé de NE PAS placer la pompe dans la partie la plus profonde du plan d eau Ceci protégera les poissons en empêchant le plan d eau de se vider complètement en cas de fuite dans la plomberie ou le filtre Des briques ou des pierres peuvent être utilisées si nécessaire pour surélever la pompe ...

Page 8: ...couverture 2 Placez la batterie dans le compartiment de la batterie a besoin 1 23A 12V la batterie 3 Replacez le couverture arrière et installer les vis Cage de pompe N enlevez ni la cage supérieure ni la cage inférieure de la pompe lorsque vous l actionnez Faire fonctionner la pompe sans la cage de filtration ou avec une cage brisée permettrait à des débris de grande taille d entrer dans la pompe...

Page 9: ... n enveloppe la turbine Assurez vous que la pompe reçoit la bonne tension Pompe en panne L interrupteur du disjoncteur de fuite à la terre GFCI peut avoir été déclenché La pompe ne reçoit pas la bonne tension Télécommande ne fonctionne pas Assurez vous que l interrupteur sur le récepteur est en mode télécommande Vérifiez l étiquette sur le dos de l émetteur et le récepteur pour s assurer qu ils so...

Reviews: