background image

2

1

3

&

6

7

 

US 1-866-877-6637 | 

 

CAN 1-866-766-3426 | www.aquascapeinc.com

www.aquascapeinc.com | 

☎ 

CAN 1-866-766-3426 | 

☎ 

US 1-866-877-6637

•  With the cage tabs released, the upper filter cage can be 

lifted to expose the pump.

•  Remove the screws 

securing the pump 
restraining bracket, 
allowing the pump to be 
lifted from the lower cage.

•  For easier pump access, 

pull the power cord free 
from the strain relief.

sufficient oxygen levels and proper 
gas exchange in the pond, helping 
to prevent fish loss. For best results 
use the AquaForce

®

 in combination 

with a de-icer. The combination of 
the AquaForce

®

 pump and a pond 

de-icer will further increase the 
pond’s oxygen levels and remove 
potentially harmful gases from the water, as well as allow 
for a back-up in case one of the devices stops working.

•  It is important to not place the AquaForce

®

 on the bottom 

of the pond during the winter, which may disrupt the 
natural thermocline found in the deeper portions of the 
pond where the fish overwinter. Instead, place the pump 
at least one foot above the 
deepest point of the pond. The 
rotational ball should be turned 
upwards, allowing the water 
to bubble at the surface of the 
pond. Bricks or stones can be 
used, if needed, to raise the 
pump to the proper level.

 

Remote Control and Receiver 
Operation 
•  Receiver Switch –

 The Receiver includes  

a switch that allows the pump to be operated  
in the two following modes:

 

O

 

Position 1

 - Operated by Remote Control

 

  

Position 2

 -  Bypass the Remote and  

operate at full flow-rate

In the event of a power loss when operating in the Remote 
Control setting, the pump will revert to its most recent flow-rate 
setting.

•  Remote Control – 

The Remote Control includes the ability 

to turn the pump on and off, as well as adjust the flow of 
the pump. Make sure the switch on the Receiver is in the 
Remote Control setting in order for the Remote to work 
properly. The Remote Control has an approximate range of 
150 feet. The range of the Remote may be reduced if there 
are obstacles between the Remote and Receiver. Use the 
included mounting holster provided to provide a location 
to store the remote control. It is recommended to mount 
the holster in an area that is protected from the outdoor 
elements.

Pond De-Icer (#39000)

PLEASE NOTE: 

The Remote 

Control and Receiver are 
paired together with their 
own unique frequency. For 
this reason Remote Control 
replacement kits include both 
Remote Control and Receiver.

•   Battery  Installation

1.

  Remove 4 screws and back cover plate.

2.

  Place battery into the battery compartment.  

Requires 1- 23A 12V battery.

3.

  Replace back cover and install screws.

Decrease 
Flow
Increase Flow
On/Off

•  

Internal Pump Cleaning –

 If you have thoroughly 

cleaned the filter cage screens and still have diminished 
flow rates, then you will need to remove the pump from  
the lower cage and inspect the impeller rotor assembly. 

•  Pull the cage release tabs outward to unlock the upper 

and lower pump cages.

•  If your rotor assembly impeller and internal pump body 

have excessive scale build-up, clean with a mild acid, 
such as white vinegar or non-abrasive calcium, lime and 
rust remover product. A sponge or soft-bristled brush that 
won’t scratch the stainless steel can be used at this time. 
Removing scale build-up will allow your pump to run like 
new again. 

•   AquaForce

®

 ready for reassembly –

 

The water chamber 

cover will only fit back onto the pump with the top of the 
tear-drop shapes lining up, along with matching the hole in 
the cover with the pin on the face of the pump motor flange.

Replacing the Impeller/Rotor Assembly

When replacing the 
AquaForce

®

 rotor-impeller 

assembly into the pump 
chamber, note the proper 
orientation. The raised key 
on the impeller face plate 
should be lined up with the 
groove in the pump housing.

RAISED KEY

PUMP FLANGE PIN

PUMP WATER

COVER HOLE

GROOVE

PUMP 

FLANGE PIN

PUMP WATER

COVER HOLE

•  Remove the four screws that hold the water cover 

chamber and inspect the impeller rotor assembly.

VIDEO ON AQUAFORCE 

PUMP MAINTENANCE & 

TROUBLESHOOTING TIPS

Pump Operation and Maintenance 

•  

Pump Cage –

 Do not remove the upper or 

lower pump cage while operating the pump. 
Failure to operate the pump without the filter 
cage or operating the pump with 
a broken cage will allow large 
debris to enter the pump, causing 
the pump to fail and voiding the 
warranty. 

•  

Pump Cage Cleaning –

  

We recommend inspecting 
your pump on a regular basis to 
ensure it is functioning properly. 
If you notice the flow-rate 
diminish, it may be due to the 
pump’s filter cage becoming 
clogged with debris. In many 
cases, the pump can simply 
be pulled from the pond for 
cleaning. Remove any debris 
stuck to the pump filter cage 
and/or use a garden hose to 
spray the cage clean. Always 
disconnect the power prior to 
performing maintenance on the 
pump. 

•  Remove any debris stuck to the 

pump filter cage and/or use a 
garden hose to spray the filter 
cage clean.

Summary of Contents for 91104

Page 1: ...le Flow Pump Remote Controlled Submersible Solids Handling Waterfall Filter Pump For Model 4000 8000 Item 91104 I N S T R U C T I O N S M A I N T E N A N C E Engineered for Continuous Use 3 Y E AR WARRA N T Y G A R A N TIE DE TRO I S A N S 3 ...

Page 2: ...ater will ensure proper gas exchange throughout the winter VISIT OUR WEBSITE DOWNLOAD A FREE COPY OF OUR CATALOG POND SQUAD INSTALLATION INSTRUCTIONS Contact Us For more information about our company or products please visit our website at www aquascapeinc com or call US 1 866 877 6637 CAN 1 866 766 3426 www facebook com AquascapeInc www youtube com aquascape4 www twitter com AquascapeInc www flip...

Page 3: ...door use Thermally protected This pump has been evaluated for use with freshwater only Input Amps Wattage See chart on next page The AquaForce includes a wide assortment of fittings to choose from Select the appropriate fitting s needed for your application The threaded collar on all of the fittings enables the AquaForce pump to be installed and removed without the need for any tools Do not use to...

Page 4: ...his reason Remote Control replacement kits include both Remote Control and Receiver Battery Installation 1 Remove 4 screws and back cover plate 2 Place battery into the battery compartment Requires 1 23A 12V battery 3 Replace back cover and install screws Decrease Flow Increase Flow On Off Internal Pump Cleaning If you have thoroughly cleaned the filter cage screens and still have diminished flow ...

Page 5: ...emote Control Not Working Check to make sure the switch located on the Receiver is in the remote control position See page 6 Check the label on the back of the receiver and transmitter to make sure they are paired to the same frequency Check to make sure the remote control battery is installed properly Replace battery if needed I N S T R U C T I O N S E T E N T R E T I E N 3 Y E AR WARRA N T Y G A...

Page 6: ...book com AquascapeInc www youtube com aquascape4 www twitter com AquascapeInc www flipboard com profile AquascapeInc Rejoignez nous sur Symbole AVERTISSEMENT Vous alertera sur la possibilité de dommages corporels ou matériels si vous ne vous conformez pas aux avertissements qui les accompagnent Le danger peut avoir une origine mécanique ou être dû à une électrocution Symboles utiles Symbole CONSEI...

Page 7: ...ussi loin que possible de l emplacement où l eau entre à nouveau dans l installation aquatique Il est recommandé de NE PAS placer la pompe dans la partie la plus profonde du plan d eau Ceci protégera les poissons en empêchant le plan d eau de se vider complètement en cas de fuite dans la plomberie ou le filtre Des briques ou des pierres peuvent être utilisées si nécessaire pour surélever la pompe ...

Page 8: ...couverture 2 Placez la batterie dans le compartiment de la batterie a besoin 1 23A 12V la batterie 3 Replacez le couverture arrière et installer les vis Cage de pompe N enlevez ni la cage supérieure ni la cage inférieure de la pompe lorsque vous l actionnez Faire fonctionner la pompe sans la cage de filtration ou avec une cage brisée permettrait à des débris de grande taille d entrer dans la pompe...

Page 9: ... n enveloppe la turbine Assurez vous que la pompe reçoit la bonne tension Pompe en panne L interrupteur du disjoncteur de fuite à la terre GFCI peut avoir été déclenché La pompe ne reçoit pas la bonne tension Télécommande ne fonctionne pas Assurez vous que l interrupteur sur le récepteur est en mode télécommande Vérifiez l étiquette sur le dos de l émetteur et le récepteur pour s assurer qu ils so...