background image

12

 

US (866) 877-6637 | 

 

CAN (866) 766-3426 | aquascapeinc.com

Connecting the Socket

•  Connect gas hose to the shut-off valve (Ex. 9) and wrench 

tighten. After making all connections, perform a leak test as 
described below.

•  Be sure to follow all applicable codes and requirements of the 

Authority Having Jurisdiction.

Installing Fire Media

•  Place lava rock or fire glass by hand. DO NOT dump bag out into tray to avoid clogging the burner with dust.
•  Position the media to no more than 1/2" above the top of the burner ring.
•  Make sure that you do not block the igniter box with lava rock to ensure proper ignition (Ex. 10).

NOTE:

 DO NOT mix or stack multiple types of fire media in the burner pan.

Pre-Use Instructions

WARNING:

 Before using this fire feature, make sure you have read, understand and are following all information 

provided in the Important Safety Information section of this manual. Failure to follow those instructions can cause 
death, serious injury, or property damage.

•  Prior to each fire feature operation, check the hose and valve for evidence of excessive wear or damage. Replace damaged 

or worn-out hoses before using the fire feature.

•  Make sure the regulator valve and hose connections are securely fastened to the feature, control system, and the tank. If 

your unit was assembled for you, visually check all connections.

WARNING:

 Failure to inspect this connection or follow these instructions could cause a fire or an explosion, which 

can cause death, serious bodily injury, or damage to property.

•  If any connections are not fastened securely, please contact your gas supplier for assistance.

Checking for Leaks

•  Use a leak detector or leak check solution to verify there are no leaks at any of the connections.
•  If a leak is detected, turn the gas OFF, reconnect, and re-test.
•  If you still detect a leak, turn gas off and contact your gas supplier.

Assembly Instructions – Natural Gas (continued)

Ex. 9

Ex. 10

Igniter 

Box

Burner 

Tube

DO NOT 

BLOCK THE 

OPENING

CORRECT

INCORRECT

CORRECT

INCORRECT

Summary of Contents for 58091

Page 1: ...peinc com I N S T R U C T I O N S M A I N T E N A N C E AUTO IGNITE FIRE FEATURES Faux Stone Fire Pit Item 58091 Fire and Water Spillway Bowl Item 58092 Fire and Water Stacked Slate Sphere Medium Item...

Page 2: ...2 US 866 877 6637 CAN 866 766 3426 aquascapeinc com...

Page 3: ...stment alteration service or maintenance can cause injury or property damage Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment Save...

Page 4: ...uctions Natural Gas 10 Installing Fire Media 12 Pre Use Instructions 12 Lighting Instructions 13 Care and Cleaning 13 Troubleshooting and Burner Checks 14 Replacement Parts 16 Warranty Information 16...

Page 5: ...8 x 10 4 Auto Ignite Power Cable 10 5 Silicone Water Tubing 58092 and 58093 not shown 6 Propane Tank Regulator and Hose 3 8 x 10 7 Natural Gas Conversion Orifice Contents 58091 58092 58093 2 4 For re...

Page 6: ...e is in use This fire feature is not to be operated by children Young children should be closely supervised when in the vicinity of this fire feature Do not hang or place clothing or other flammable m...

Page 7: ...feature Certain areas of this fire feature will become too hot to touch when in use To avoid burns do not touch hot surfaces until the unit has cooled unless you are wearing protective gear such as i...

Page 8: ...nnection device compatible with the connection for the appliance Propane tank must be arranged for vapor withdrawal The propane tank must have a tank collar to protect the tank valve Propane cylinder...

Page 9: ...rpret this free ow of gas to be a leak c The connection safety feature will reduce gas ow from the regulator to the appliance to a minimal level d Be sure that the burner control valve is closed prior...

Page 10: ...Make sure you check the burner and burner ports as well Connect gas line to tank by turning knob clockwise hand tighten only Ex 3 Disconnecting the Propane Tank Make sure the valve on the propane tank...

Page 11: ...er lighting rotate the burner control knob counterclockwise to LOW setting Observe the flame and make sure all burner ports are lit The flame height should be no higher than 15 21 inches tall Installi...

Page 12: ...llow those instructions can cause death serious injury or property damage Prior to each fire feature operation check the hose and valve for evidence of excessive wear or damage Replace damaged or worn...

Page 13: ...lighting rotate the control knob counterclockwise to the LOW setting Observe the flame and make sure all burner ports are lit The flame height should be no higher than 15 21 inches tall EX 12 8 Adjus...

Page 14: ...tion outdoors away from children 2 Carefully remove the media and store the components at to protect them from breakage 3 Always cover feature when not in use 4 Store in a cool dry location away from...

Page 15: ...feature and the gas source The flame is being obstructed at the burner ports Make sure that the gas ports on the burner are free of any obstructions so that the flame can flow naturally Sudden drop i...

Page 16: ...f this product and are not covered under this warranty Some color and texture variation is typical of material and finish for this product and is not covered under this warranty Cast concrete is a han...

Page 17: ...om AUTO IGNITE FIRE FEATURES I N S T R U C T I O N S E T E N T R E T I E N Faux Stone Fire Pit R f rence 58091 Fire and Water Spillway Bowl R f rence 58092 Fire and Water Stacked Slate Sphere Medium R...

Page 18: ...18 US 866 877 6637 CAN 866 766 3426 aquascapeinc com...

Page 19: ...retien incorrect peut entra ner des blessures ou des dommages mat riels Lisez attentivement les instructions d installation d utilisation et d entretien avant d installer ou de r parer cet quipement C...

Page 20: ...ort feu 28 Instructions de pr utilisation 28 Instructions d allumage 29 Entretien et nettoyage 29 D pannage et v rifications du br leur 30 Pi ces de rechange 32 Informations sur la garantie 32 Faites...

Page 21: ...n pour l allumage automatique 10 5 Tuyau d eau en silicone 58092 and 58093 pas montr 6 R gulateur et tuyau de r servoir du propane 3 8 x 10 7 Orifice de conversion de gaz naturel Contenu 58091 58092 5...

Page 22: ...orsqu ils se trouvent proximit de ce foyer Ne pas suspendre ni placer de v tements ou d autres mat riaux inflammables sur le foyer ou proximit de ce dernier Toute grille ou tout dispositif de protecti...

Page 23: ...tre touch es lors de l utilisation Pour viter les br lures ne touchez pas les surfaces chaudes tant que l appareil n a pas refroidi sauf si vous portez des quipements de protection tels que des cache...

Page 24: ...r servoir pour prot ger la valve du r servoir La bouteille de propane doit contenir un robinet d arr t tel que sp cifi dans la norme pour le gaz comprim Raccord de sortie et d entr e de la vanne de bo...

Page 25: ...e de commande du br leur est ferm e avant d ouvrir la soupape de service de la bouteille de GPL pour garantir que le dispositif de limitation de d bit de raccordement ne se d clenche pas par erreur e...

Page 26: ...r et le br leur Branche la conduite de gaz au r servoir en tournant le bouton dans le sens des aiguilles d une montre serrez la main uniquement Ex 3 D connexion du r servoir de propane Assurez vous qu...

Page 27: ...e des aiguilles d une montre jusqu au r glage BAS Observez la flamme et assurez vous que tous les orifices du br leur sont allum s La hauteur de la flamme ne doit pas d passer 15 21 pouces de hauteur...

Page 28: ...des blessures graves ou des dommages mat riels Avant chaque fonctionnement du foyer v rifiez le tuyau et la vanne pour d tecter toute trace d usure excessive ou de dommages Remplacez les tuyaux endom...

Page 29: ...r glage ARR T Observez la flamme et assurez vous que tous les orifices du br leur sont allum s La hauteur de la flamme ne doit pas d passer 15 21 pouces de hauteur Ex 12 8 R glez la flamme la hauteur...

Page 30: ...ieur hors de la port e des enfants 2 Retirez soigneusement le support et entreposez les composants plat pour les prot ger des dommages 3 Couvrez toujours le foyer lorsqu il n est pas utilis 4 Entrepos...

Page 31: ...ntre le foyer et la source de gaz La flamme est obstru e aux orifices du br leur Assurez vous que les orifices de gaz sur le br leur sont libres de toute obstruction afin que la flamme puisse circuler...

Page 32: ...du mat riau et de la finition de ce produit et ne sont pas couvertes par cette garantie Le b ton coul est un processus fini la main Ainsi les finitions GFRC varieront selon l unit Il y aura une varian...

Reviews: