pH = 7.47 COND = 1.48
ORP= 522 FLOW = ON
FAC= 0.45 TEMP =25.8
LSI= 2.02 ALARM= OFF
CALIBRATION MODE
CHOOSE CAL. MODE ?
UP/DOWN SELECT
PRESS ENT TO EXIT
#!,)"2!4)/.-/$%
#/-"/#!,)"2!4)/.
50$/7.3%,%#4
%.4%24/#/.&)2-
#!,)"2!4)/.-/$%
P(#!,)"2!4)/.
50$/7.3%,%#4
%.4%24/#/.&)2-
2
System Configuration
2
System Configuration
Default Screen
The factory setting is to show the ‘default’ screen on power-up. The
Aquarius ‘default’ screen displays Company Name, name identifier
of the equipment, firmware version, and the current system date and
time. If there is an active system alarm, details will be displayed on
the fourth line instead of LSI and alarm reading. Users may also
configure the controller to show the current sensor readings instead
of the default screen. If the sensor readings screen is selected, all
current values of measured parameters are displayed.
Calibration – Access from the CAL button
The following instructions provide a detailed explanation of the
Probes, Conductivity, and Temperature Calibration. Calibration of
the pH probe and verification of the ORP probe are very similar
processes. When calibrating the probes the user has the option of
setting both probes in combination or setting each probe individually.
Only use individual calibration when a single probe has been
replaced or adjusted.
Press the CAL button on the front panel. The calibration mode
selection screen will appear on the alphanumeric display. By
pressing the
↑
(Up) and
↓
(Down) arrows the user can cycle all of the
calibration modes indicated in the menu tree diagram.
Combination Calibration Mode
As both the pH and ORP sensors are contained within the one
electrode it is possible to perform both pH calibration and ORP
verification in one step. For this you will need Aquarius combination
buffers.
Part Number:
AS7086 - pH 7.01 & 86 mV
Part Number:
AS4250 - pH 4.01 & 250 mV
Erase Water Usage Meter (WUM) Totals Mode
WUM total value can be reset from here. Pressing ENT will bring
you to a second screen for confirmation.
pH Calibration Mode
To calibrate pH separately press ENT for pH calibration.
Then place the probe in pH solution and press ENT
when ready. The screen will display the message
‘PROBE STABILISING PLEASE WAIT’. When completed the screen
will display the value and prompt the user to press ENT to continue.
At this point, the menu will return to the ‘CHOOSE CAL MODE ?’
screen.
Part Number:
AS7004 - pH 4.01
Part Number:
AS7007 - pH 7.01