Advantages
Fully integrated “fit and forget” digital viscosity and temperature measurement for monitoring and control
Two 4–20 mA outputs of kinematic viscosity and temperature/density
Modbus/RS-485 communications output of all parameters, including calculated density and calculated
kinematic viscosity at operating temperature
Continuous measurement
No moving parts means virtually no maintenance
PFA-coated tines for asphaltene rich fuels
Integral Class B PT100 temperature sensor
Hazardous-area approved (ATEX and CSA)
Insensitive to vibration
Direct insertion meter suitable for high-line pressure
PC configuration tools for diagnostics and data logging
Controller with preadjusted selectable functions
Adapter for existing Viscosity system or direct insertion
Matched components for easy installation
Scope of Supply
Viscomaster
HFVM-B
Viscosity Sensor Dynamic
For viscosity and temperature measurements
HFVM-R
Viscosity Sensor
For viscosity and density measurements
Standard
Adapter
In-Line
The In-Line viscosity retrofit kit provides a simple, direct replacement for
existing meters and the installation solution for new building
Flow
Through
Chamber
The capillary viscosity retrofit kit provides a simple, direct replacement for
existing capillary meters
Flange
The flange adapter viscosity retrofit kit provides a simple, direct
replacement for existing VAF or Nakakita viscosity meters
3
Viscosity Sensor installation / implementation
3.1
Planning
Topics covered in this chapter:
Installation checklist
Best practices
Power requirements
Other installation considerations
Recommended installations for the HFVM
Perform a pre-installation meter check