Shows the cell’s operating time in hours.
Shows how many hours the unit was connected to the power supply.
6.3 Alarm messages :
Indicates that there is no water flow through the electrolysis cell (flow switch).
Indicates that the water temperature through the cell is below 15°C.
Indicates that there is no water in the cell (conductivity measurement).
Low salt rate (Lower than 2.5g/l).
Too much power on the cell. Possible short circuit. Check the salt concentration.
No power on the cell, open circuit, a cable is cut or disconnected. Check scale formation.
6.4 Operation indicator:
Malfunction indicator. See details on the display screen.
Lit up when the cell is in operation.
Polarity reversal indicator, on in a way and off in the other.
Indicator lit up between two polarities directions.
Lights up when the pool is covered.
Indicates that the filtration operating time is too short compared to the temperature of the water in
thepool.
Minimum filtration operating time depending on water temperature:
Temperature °C
Time Hours
Temperature °C
Time Hours
16
8
26
13
18
9
28
16
20
10
30
19
22
11
Plus
24/24
24
12