24
Midas range commissioning
THE MIDAS PRODUCT RANGE IS PRE-SET TO A SAFE MAXIMUM SHOWER TEMPERATURE. SHOULD IT BE
NECESSARY TO RESET THE MAXIMUM TEMPERATURE POSITION, PLEASE OBSERVE THE FOLLOWING PROCEDURE.
WE RECOMMEND THE MAXIMUM OUTLET TEMPERATURE IS SET TO 46oC.
1
Ensure that the hot water system is at normal maximum temperature.
! Should unacceptable damage to the temperature knob end cap occur when removing it from the temperature knob,
please contact Aqualisa customer service on 01959 560010 to arrange a replacement.
2
Turn the temperature control knob to the mid-blend position (with the button at the top of the knob).
3
Carefully remove the end cover cap using a small flat bladed screwdriver if necessary.
4
Remove the central fixing screw, pull the knob clear and set aside.
5
Turn the valve on.
6
Using a digital thermometer adjust the temperature control to the required MAXIMUM temperature setting.
We recommend the MAXIMUM outlet temperature is set to 46oC.
7
Turn the valve off.
8
Ensuring the temperature override button is pushed in, place the knob onto the valve ensuring the MAX temp position is
aligned with the temperature setting indicator.
!
9
Secure the knob to the valve and refit the knob insert.