1
Hold the front and rear of the grey rail end and carefully, but firmly, pull the chrome cover away
from the rail end assembly as shown.
2
Prepare two fixing points 765mm vertically apart using a spirit level to facilitate if necessary, using the fixings provided if
suitable.
3
Ensuring the handset cradle is on the left side of the rail, pass the rail through the handset holder
whilst keeping the slider button depressed.
4
Current water supply regulations state the handset should not be allowed to pass a point 25mm
above the spill over level of the bath or shower tray. If this cannot be achieved, the hose restraint
must be fitted. This is fitted to the rail under the handset holder.
5
Fit the rail into the rail end bodies ensuring the indents in the rail are facing the finished wall
surface.
6
Secure the rail assembly to the wall using the screws provided ensuring the rail and rail end bodies remain firmly engaged.
7
Fit the rail end covers into position and push firmly into place.