![Aqualisa Midas 100 Installation Manual Download Page 16](http://html1.mh-extra.com/html/aqualisa/midas-100/midas-100_installation-manual_2960139016.webp)
16
1
Hold the front and rear of the grey rail end and carefully, but firmly, pull the chrome cover away
from the rail end assembly as shown.
2
Prepare two fixing points 470mm vertically apart using a spirit level to facilitate if necessary using suitable fixings to
accept No. 8 non-rusting screws (not supplied).
3
Ensuring the handset cradle is on the left side of the rail, pass the rail through the handset
holder whilst keeping the slider button depressed .
5
Fit the rail into the rail end bodies ensuring the indents in the rail are facing the finished wall
surface.
Midas 100 adjustable height head installation
4
Current water supply regulations state the handset should not be allowed to pass a point 25mm
above the spill over level of the bath or shower tray. If this cannot be achieved, the hose restraint
must be fitted. This is fitted to the rail under the handset holder.
7
Fit the rail end covers into position and push firmly into place.
6
Secure the rail assembly to the wall using No 8. non-rusting round head screws of suitable length ensuring the rail and rail
end bodies remain firmly engaged.