Aquatique Thermo

installation instuctions

page 1

Aquatique

®

Thermo

shower valve

Summary of Contents for Aquatique Thermo 500.00.01

Page 1: ...Aquatique Thermo installation instuctions page 1 Aquatique Thermo shower valve...

Page 2: ...Aquatique Thermo installation instuctions page 2 Shower systems Aquatique Thermo Exposed valve Chrome 500 10 01 Gold 500 10 04 Aquatique Thermo Concealed valve Chrome 500 00 01 Gold 500 00 04...

Page 3: ...Aquatique Thermo installation instuctions page 3 Components Exposed Concealed Literature not shown Literature not shown...

Page 4: ...s overleaf to reverse the valve The Aquatique Thermo exposed valve is supplied complete with 15mm compression elbow fittings at 198mm centres The Aquatique Thermo concealed valve is NOT supplied with...

Page 5: ...pplied and the hot supply from the nearest convenient draw off point Account must be taken of pressure drops that may occur when other draw off points are used while the shower is in use Pipe work can...

Page 6: ...correctly and safely Aquatique Thermo is supplied with universal fittings Please note that the fixing template is supplied as a guide only we thus recommend that you assemble the valve and measure th...

Page 7: ...the cold inlet connection ensuring the small O ring is facing the incoming flow prior to connection of the elbow assemblies 7 Carefully slide the cover plates onto the elbows to cover the compression...

Page 8: ...uts into position and rotate them so the locking screw is out of site before securing them using the 2 5mm key Remove the mounting ring from the rear of the valve using the 2 5mm hexagonal key provide...

Page 9: ...product built in to a solid wall chase out a suitable recess in the wall to receive the valve and pipe work If installing the valve in a concealed panel mounted situation in most cases it will be nece...

Page 10: ...the warranty should access to service connections be denied by the use of solid setting infill material Fill in the chase ensuring the valve body elbows and outlet are not cemented into the wall Suita...

Page 11: ...aximum temperature adjustment if required Temperature adjustment is limited by inserting the limiting pins provided into the small holes in the face of the cartridge The pins are fitted as follows 1 E...

Page 12: ...arkings Check the flow rate recommendations with the heater manufacturer Symptom Water output is either all hot or all cold Possible cause Reversed inlet supplies Check that the pipe work is laid out...

Page 13: ...ply Hot water cylinder Supply Pressure reducing valve if required Supply Vent and draw off pipe to hot water Underside of cistern Highest point must be 1m below underside of cistern Hot water cylinder...

Page 14: ...60010 Republic of Ireland 01 844 3212 Brochure Hotline 0800 652 3669 Website www aqualisa co uk Email enquiries aqualisa co uk Please note that calls may be recorded for training and quality purposes...

Page 15: ...Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more...