Aquatique Thermo
installation instuctions
page 10
Insert the valve into the mounting ring and
tighten the locking screw using the 2.5mm key
provided.
5
Using suitable
‹÷¢
” BSP unions, connect the inlet and outlet pipes.
7
If the valve is being installed for use with a gas fired instantaneous
(multipoint) water heater or a combination boiler, the cold water flow
regulator must be fitted at this stage by insertion into the cold inlet
connection ensuring the small ‘O’ ring is facing the incoming flow,
prior to connection of the elbow unions.
6
8
Aqualisa reserves the right to revoke the terms of the warranty should access
to service connections be denied by the use of solid setting infill material.
!
Fill in the chase ensuring the valve body elbows and outlet are not cemented
into the wall. Suitable non-setting infill material such as paper, polystyrene
etc. should be wrapped around the components and a plaster finish applied.
9
Using a silicone based lubricant or liquid
soap, lubricate the wall plate grommet and
push onto the valve flush with the wall
surface. A thin bead of silicone based
sealant may be required to seal the wall
plate to the wall surface.
10
Fit the temperature lever and on/off control
assembly to the valve body with the lever in
a vertical position and the on/off control
horizontal. Secure the assembly to the valve
body with the four screws, hand tight only.