7
Control Start-Up Procedures
Set Hardness
The HARDNESS is entered into the control valve by
pressing the
“NEXT”
and
buttons simultaneously
for 3 seconds.
The default HARDNESS setting is 20. The
or
buttons adjust the HARDNESS from 1 to 150. Press
the
“NEXT”
button to advance to the SET DAY
OVERRIDE function.
Set Day Override
The control valve allows for a DAY OVERRIDE. This
setting allows you to input the maximum number of
days that can pass between regenerations.
The default DAY OVERRIDE is 14. The
or
but-
tons adjust the DAY OVERRIDE from 1 to 28 days.
Press the
“NEXT”
button to advance to the TIME OF
REGENERATION function.
Time of Regeneration
The TIME OF REGENERATION allows you to input
the actual time you want the regeneration of your
water conditioner to occur. Normally, water soften-
ers regenerate at 2:00 AM and water filters regener-
ate at midnight.
The default TIME OF REGENERATION is 2:00 AM.
Adjust the HOURS by pressing the
or
keys.
Use care when verifying AM or PM. AM and PM will
toggle after 12 AM. Once the HOUR is correctly set
press the
“NEXT”
button to program the MINUTES.
Adjust the MINUTES by pressing the
or
keys.
Once the MINUTES are correctly set, press the
“NEXT”
button to return to normal operation.