1.6.c Connecting Gas Backup Heater to Heat Pump
To support a direct connection to a gas backup heater, AquaCal
®
heat pumps are equipped with optional
terminal blocks on the microprocessor. The microprocessor is located on the low-voltage side of the electrical
enclosure.
PLEASE NOTE -
If the heat pump is connected and using an external controller with a SMART bus
connection, the gas backup option is not available. The gas backup should be connected
directly to the external controller.
DANGER
Failure to heed the following will result in injury or death.
l
Deactivate power while routing wiring to control board.
l
Follow all National Electric Codes (NEC) and/or State and Local guidelines.
WARNING
Failure to heed the following may result in injury or death.
l
This section is only for qualified installers who are familiar with the swimming pool and spa safety standards.
l
The installer must be familiar with service industry techniques.
NOTICE
Failure to heed the following may result in damage to equipment.
l
The wire size connecting the gas heater to the heat pump must be 22-gauge (minimum), 2-conductor, low-voltage
wire.
l
Use direct connection (
dry contact)
provided on the microprocessor for the gas heater.
l
Failure to follow the manufacturer's installation requirements for a fireman (cool down) switch may result in
damage to the gas heater.
1
-
Ins
ta
lla
tion
Summary of Contents for GBB
Page 2: ......
Page 25: ...Page 21 Configure Call Flex Enter Installer Menus then proceed 1 Installation...
Page 29: ...Page 25 1 Installation...
Page 32: ...Page 28 1 Installation...
Page 36: ...Page 32 1 Installation...
Page 37: ...Page 33 Configure for Scheduled Mode Enter Installer Menus then proceed 1 Installation...
Page 41: ...Page 37 1 Installation...
Page 43: ...Page 39 1 Installation...
Page 46: ...Page 42 1 Installation...
Page 50: ...Page 46 1 Installation...
Page 53: ...Page 49 1 Installation...
Page 55: ...Page 51 1 Installation...
Page 74: ...Page 70 l Follow all National Electric Codes NEC and or State and Local guidelines 3 Appendix...
Page 77: ......
Page 78: ......