GENERAL WARNINGS 

- This filter is an equipment for the treatment of drinking water made in compliance with the DM. 
25/12  and  DM.  174/04, the  user  must  use  it  in full  compliance  with this manual  in  order  to  avoid 
potential risks to health or safety; 
- This filter is suitable for the filtration and treatment of drinking water as defined by the competent 
authorities  of  the  place  of  installation  and,  in  any  case,  for  liquids  for  food  use,  with  PH  close  to 
neutral; 
- Do not use in presence of water with unknown origin or microbiologically not pure, without providing 
for the use of an adequate disinfection system; 
-  Use  the  filters  in  compliance  with  the  operating  pressures  declared  by  the  manufacturer.  With 
presence  of  high  pressures  in  the  circuit  or  "water  hammer",  protect  the  device  by  installing  a 
pressure reducer upstream; 
- Except for special filters, use the filters with liquids at room temperature (20-25°C), however within 
the limits indicated by the manufacturer. If used upstream of a boiler, it is recommended to install a 
non-return valve to prevent boiling water from entering the filter; 
- Do not use the containers for the filtration of compressed air, oil or gas, even at low pressures. 
- Do not use these filters in environments exposed to freezing temperatures or high temperatures. 
Therefore,  installation  outdoors  or  in  places  exposed  to  bad  weather  or  ultraviolet  rays  is  not 
recommended; 
- This equipment requires regular periodic maintenance in order to ensure the maintenance of the 
drinking water requirements of the treated water.

 

 
INSTALLATION 

The installation of the filter must be performed by qualified personnel capable of issuing a regular 
declaration of conformity. 
 
The typical filter assembly scheme is the 
one shown in the image alongside. 
 
It  is  advisable  to  create  a  bypass  to 
ensure maintenance of the filter cartridge 
without eliminating the supply of water to 
the users. 
 
During the assembly phase it is important 
to respect the inlet / outlet  direction (IN-
OUT)  indicated  on  the  filter  head.  This  is  necessary  to 
allow the cartridges to work correctly. 
 
To install the filter on the wall, use the appropriate wall 
bracket  (optional),  which 
allows  for  correct  fixing 
and  proper  spacing  from 
the  wall,  necessary  to 
ensure the opening of the 
filter  with  the  use  of  the 
appropriate key. 
 

Summary of Contents for FP2

Page 1: ...FP3 filters can contain cartridges of various kinds depending on the type of treatment to be carried out on the incoming drinking water In particular AQUA spa makes available for these filters Wire wound cartridges Mod FA Melt Blown polypropylene cartridges Mod FR E FR N FR A Washable mesh cartridges Mod RLA Pleated cartridges Mod PL Ultrafiltration cartridges Mod UF Steel cartridges Mod AC Activa...

Page 2: ......

Page 3: ...atment on the drinking water entering the network The filters are available with transparent sumps and opaque sumps in different heights with different pipe connection sizes with and without brass inserts and in two FP2 or three FP3 pieces WHITHOUT BRASS INSERTS WITH BRASS INSERT Their typical installation scheme is as follows ...

Page 4: ...revent boiling water from entering the filter Do not use the containers for the filtration of compressed air oil or gas even at low pressures Do not use these filters in environments exposed to freezing temperatures or high temperatures Therefore installation outdoors or in places exposed to bad weather or ultraviolet rays is not recommended This equipment requires regular periodic maintenance in ...

Page 5: ...the wall is 80 mm The minimum distance from the floor is 25 mm The recommended distance is instead of 100 mm or more Depending on the size of the filter purchased it is possible to determine the fixing point of the bracket using the following table where the dimensions of the FP3 filter can also be deduced Similar considerations can be made for FP2 filters The relative dimensions can be found in t...

Page 6: ...ectly to the device Pipes can be used for welding pressure or with union Use fittings with cylindrical thread with GAS or BSP pitch Do not use fittings with tapered threads When fixing the fittings to the head avoid using sealing pastes hardening liquids silicone hemp or other but only Teflon tape After fixing open the taps and check that there are no leaks or drips ...

Page 7: ...and remove any dust or dirt present in the filter even after its assembly After these operations the filter is running regularly These operations must be repeated every time the filter cartridge is replaced or serviced CLEANING AND MAINTENANCE ATTENTION This equipment requires regular periodic maintenance in order to ensure the potability requirements of the treated drinking water and the maintena...

Page 8: ...head by hand Reactivate the water network by keeping the vent valve open until all the air present in the network has escaped after which close the vent valve If the filter shows dripping tighten the sump with the key Regardless of the type of cartridge used at the end of each cleaning or maintenance operation let the water run for a few minutes before using it The frequency of intervention is lin...

Page 9: ...tem is used according to the instructions given by the manufacturer Installation and maintenance are carried out following the manufacturer s instructions The replacement under warranty is made only against the return of defective material and after verifying the nature of the defect The warranty is intended limited to the replacement of the part recognized as defective and excludes any other righ...

Reviews: