ADSP7000634
rev. 1.3
23/09/2020
19/36
The t.on and t.oF entries are visible on the Settings Menu only in the case in which the pump is
programmed to pilot the solenoid valve, otherwise by C.d.t, by pressing the F key, it goes back to
the first entry of the Settings Menu.
To go back to the Programming Menu, to the
InP
entry, just press
Enter
for 3 seconds from any entry of the Menu.
Fig. 19 - Settings Menu
4.0 ALARMS
4.1 MOTOR ALARM
The motor alarm is present in all CD pump models with motors in direct current.
In the event of excessive absorption of the motor due to malfunction, or if the power supply voltage of the pump (30
Volts) drops below 24 Volts, the pump performs three attempts to restart the motor. The three attempts carried out
before the alarm signal are respectively after 5 seconds, then 10 seconds and finally after 15 seconds from the
previous stop. The alarm is signalled as follows:
Acoustic signal through the buzzer (if installed on the pump), with a frequency of 1 second on and 1 second
off;
flashing red LED;
“
not
” flashing on the display;
In this alarm status the motor is stationary. Restoring normal status to the equipment is carried out by turning
off/turning on the switch or through the power supply.
4.2 MAINTENANCE ALARM
The maintenance alarm is activated when the pump has been running for longer than the time set in the relative
O.F.d
sub-menu (see
Settings Menu).
If you set 0.00 (h.mm) as a time value for the maintenance alarm, it will be disabled.
This is reported by the pump as follows:
Audio signal via the buzzer (if there is one on the pump) if enabled (see
A.bu
on the “Settings Menu”) with a
frequency of 1 second on and 1 second off;
flashing red LED;
“
OFd
” flashing on the display;
In this alarm status the motor is stationary. To disable the alarm, you need to go to the
t.F.P
entry (pump operating
time) in the Statistics Menu and reset the value.
Summary of Contents for DGTEC CD
Page 25: ...ADSP7000634 rev 1 3 23 09 2020 25 36 ANNEX A Overall dimensions ...
Page 27: ...ADSP7000634 rev 1 3 23 09 2020 27 36 ANNEX C Exploded views ...
Page 33: ...ADSP7000634 rev 1 3 23 09 2020 33 36 ANNEX G Menu Layouts Initial Menu User Menu ...
Page 34: ...ADSP7000634 rev 1 3 23 09 2020 34 36 Programming Menu Statistics Menu Settings Menu ...
Page 36: ...ADSP7000634 rev 1 3 23 09 2020 36 36 DGTEC CD ...