ADSP7000634
rev. 1.3
23/09/2020
5/36
1.3 TECHNICAL FEATURES
1.3.1 ELECTRICAL FEATURES
For the power supply value we recommend reading the label on the pump!
1.3.2 PERFORMANCE
Maximum height of the suction tube: 1.5 m
Flow rate and back-pressure: refer to Table 1, read the label on the pump to identify the corresponding
model.
Codes
Power supply
Motor
Type
Flow
rate (l/h)
Backpressure
(bar)
Peristaltic
Tube
PT100
ADD400601C000000
(not available)
24 VAC/VDC
24 VDC
6
1
Santoprene
X
ADD4006010000000
230 VAC
24 VDC
6
1
Santoprene
X
ADD401000C000000
(not available)
24 VAC/VDC
24 VDC
10
0
Santoprene
X
ADD4010000000000
230 VAC
24 VDC
10
1
Santoprene
X
Tab. 1
The pump codes that may be ordered are found in the table. The manual also proposes pumps with unavailable
characteristics in the 4 models in the table (conductivity probe with PT100 sensor to read the temperature and 24
VDC output to activate the solenoid valve to dose solid detergent).
Operating ambient temperature: 0 ÷ 45°C
Transport and Packaging Temperature: -10 ÷ 50°C
Protection rating: IP65
2.0 INSTALLATION
2.1 GENERAL RULES
Pump installation must be carried out as follows:
In vertical position with an uncertainty not greater than +/-15°.
Away from sources of heat in dry locations, at a maximum temperature of 40°C and a minimum of 0°C.
In a ventilated environment and easily accessible to an operator for periodic maintenance.
Above the level of the liquid that needs to be dosed, at a height of 1.5 metres maximum.
Do not install the pump above the tank when using liquids that emit fumes, unless it is sealed shut.
2.2 INSTALLATION KIT
When you purchase the pump, it includes everything required for correct installation, specifically:
Bracket;
Dowels and screws;
Level probe (
optional
);
Foot strainer (see
Fig. 1- a
);
PVC suction and delivery tubes (4 m.);
Conductivity Probe and Electrodes;
Tank inlet fitting (see
Fig. 1- b
);
Summary of Contents for DGTEC CD
Page 25: ...ADSP7000634 rev 1 3 23 09 2020 25 36 ANNEX A Overall dimensions ...
Page 27: ...ADSP7000634 rev 1 3 23 09 2020 27 36 ANNEX C Exploded views ...
Page 33: ...ADSP7000634 rev 1 3 23 09 2020 33 36 ANNEX G Menu Layouts Initial Menu User Menu ...
Page 34: ...ADSP7000634 rev 1 3 23 09 2020 34 36 Programming Menu Statistics Menu Settings Menu ...
Page 36: ...ADSP7000634 rev 1 3 23 09 2020 36 36 DGTEC CD ...