ADSP7000634
rev. 1.3
23/09/2020
7/36
2.3 ASSEMBLY
We always recommend wearing protective masks, gloves, goggles and any other PPE during all
installation steps and when handling chemical products.
WALL MOUNTING
Proceed as follows to secure the pump to the wall:
Fix the bracket to the wall using the plugs and screws supplied.
Place the pump on the bracket.
Ensure the fixing is stable.
It is also recommended to install the pump in a dry environment, away from heat sources and
exhaust vapour.
2.3.1 CONDUCTIVITY PROBE CONNECTION
The provided conductivity probe is a 2-wire conductivity meter type. Upon request, it is possible to receive a 4-wire
temperature-compensated probe. The codes set out in Tab. 1 do not consider this option.
Fig. 3 Conductivity Probe
Fig. 4 - Conductivity card
To carry out correct installation of the conductivity probe onto the dishwasher, verify the points detailed hereunder:
install the probe in the washing tank;
the probe electrodes must be at least 4 centimetres below the maximum filling level;
install the probe close to the washing pump filter;
Do not install
the probe close to edges, electrical resistance, detergent input and at the bottom
of the tank.
Should the dishwasher not be predisposed to assemble the conductivity probe, make
a 23 mm hole in the washing tank wall.
Summary of Contents for DGTEC CD
Page 25: ...ADSP7000634 rev 1 3 23 09 2020 25 36 ANNEX A Overall dimensions ...
Page 27: ...ADSP7000634 rev 1 3 23 09 2020 27 36 ANNEX C Exploded views ...
Page 33: ...ADSP7000634 rev 1 3 23 09 2020 33 36 ANNEX G Menu Layouts Initial Menu User Menu ...
Page 34: ...ADSP7000634 rev 1 3 23 09 2020 34 36 Programming Menu Statistics Menu Settings Menu ...
Page 36: ...ADSP7000634 rev 1 3 23 09 2020 36 36 DGTEC CD ...