8
Connecting your SPLASHER
ADJUSTMENTS
1. Connect the SPLASHER to your hoses
2. Gently place the SPLASHER in the water.
3. To enable air to be driven from the unit, place the last pipe on your inlet while your pool pump is
running. This will fill the unit with water and allow it to sink to the pool floor.
4. Attach the flow control valve to the weir, with the arrow in the direction of the water flow.
5. Attach the free end of the pool hose to the free end of the flow control valve.
6. Switch on the pool pump and the SPLASHER will start to operate.
Flow Control Valve
The flow control valve is supplied set at its most commonly used setting. Should SPLASHER not operate
continuously at this setting adjust the flow control valve by changing the positions of the springs to
achieve optimum movement of the SPLASHER. Should the SPLASHER only operate (or fail to operate)
with the hose connected directly to the weir, this indicates that the filtrations system is in need of ser-
vicing, there might be leaks in the system or the circulation pump is underpowered. Pool cleaners are
certified as being compliant with applicable safety standards such as IAMPO SPS4.
Do not block the suction fittings in the pool, the suction
opening on the cleaner, or the cleaner hoses with
any part of your body. Do not expose your hair, loose
clothing, jewelry, etc. to any suction outlet fittings in the
pool/spa or on the cleaner.
Warning! Do not detach the cleaner from the hose while
the pump is on.
DIAPHRAGM ASSEMBLY
MAINTENANCE