Technical Data

Symptom

Cause

Solution

No hot water

- water flow too low to activate
  flow switch.
- shower head is blocked with dirt
  or lime
- circuit breaker off
- safety thermal cut-out tripped

- increase flow volume
- clean shower head or remove
  lime scale
- turn breaker on
- reset thermal cut-out

The unit is not being switched on, elec-
tric supply and flow available

- the minimum flow to activate unit
  has not been achieved.
- filter in cold water connection
  line blocked

- increase flow volume
- clean the filter screen after
  shutting of the cold water supply

Water not hot enough

- water flow too high
- heat setting too low

- reduce water flow
- turn temperature control knob to
  the right (max. position)

Troubleshooting

Model 

1

DH 60

DH 80

DH 100

DH 100 C

Item No.

227259

227329

234029

234030

Design

Pressure type

Current

Single phase - 60/50

 Hz

208 V

9.36

 kW

  /  45

 A

220 V

5.5

 kW

  /  25

 A

7.3

 kW

  /  33

 A

8.4

 kW

  /  38

 A

Not available

230 V

6.0

 kW

  /  26

 A

8.0

 kW

  /  35

 A

9.2

 kW

  /  40

 A

Not available

240 V

6.5

 kW

  /  27

 A

8.7

 kW

  /  36

 A

10.0

 kW

  /  42

 A

Not available

Recommended circuit 

breaker size 

2

30

 A

40

 A

50

 A

50

 A

Wire gauge, copper 

3

10

 AWG

8

 AWG

6

 AWG

6

 AWG

Minimum water flow to 

activate unit

0.76–0.92

 gpm

 

2.9–3.5

 l/min

0.85–1.0

 gpm

 

3.2–3.8

 l/min

0.92–1.1

 gpm

 

3.2–4.0

 l/min

0.92–1.1

 gpm

 

3.4–4.0

 l/min

Minimum water pressure to 

activate unit

3

 psi

  /  0.2

 bar

4.4

 psi

  /  0.3

 bar

4.4

 psi

  /  0.3

 bar

4.4

 psi

  /  0.3

 bar

Max. working pressure

150

 psi

 / 10

 bar

Volume of water in unit

0.13

 gal

 / 0.5

 l

 

Weight

3.44

 lb

 / 1.56

 kg

Dimensions 

(H x W x D)

13 

¾

” / 350

 mm

  x  7 

¼

” / 210

 mm

  x  3 

¾

” / 100

 mm

Plumbing connections

G ½”

1

  Suitable for supply with cold water 

2

  This is our recommendation as the manufacturer. Check local codes for compliance if necessary. Tankless water heaters are considered a non-continuous load.

3

  Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.

WARRANTY

Make any warranty claim in the country where you purchased the appliance. In such cases, please contact our representation 
or the importer.

Our warranty applies only if:
– These installation instructions have been observed
– Exclusively accessories designated for this appliance have been used
– All required steps up to and including commissioning have been carried out by a qualified contractor
– Maintenance as specified has been carried out
– Exclusively our spare parts have been used for repairs

Environment and recycling

Please help us protect the environment. Dispose of the appliance and its packaging in accordance with national regulations.

Summary of Contents for DH 100

Page 1: ......

Page 2: ...ntaneous water heater differs from conventional storage type water heaters in several ways It does not store hot water Instead water is heated instanta neously as it flows through the unit The powerful heating ele ments are activated by a flow switch as water is drawn from a hot water faucet connected to the DH unit Due to the absence of stand by losses the DH series has greater energy efficiency ...

Page 3: ...tion 5 Cold water connection 6 Lower mounting hole 7 Wiring block 8 Upper mounting hole 9 Rubber grommet for connection cable 10 Cover securing screw 11 Depth for mounting screw 12 Rear wall installation 13 Filter screen 14 Union nut and washer provided by installer Figure legend ...

Page 4: ...tion 5 Cold water connection 6 Lower mounting hole 7 Wiring block 8 Upper mounting hole 9 Rubber grommet for connection cable 10 Cover securing screw 11 Depth for mounting screw 12 Rear wall installation 13 Filter screen 14 Union nut and washer provided by installer Figure legend ...

Page 5: ...OUNTING AND PLUMBING MUST BE COMPLETED BE FORE PROCEEDING WITH ELECTRICAL HOOK UPS WARNING AS WITH ANY ELECTRIC APPLIANCE FAILURE TO ELECTRICALLY GROUND UNIT MAY RESULT IN SERIOUS INJURY OR DEATH THE UNIT S PLASTIC COVER MUST BE INSTALLED BEFORE THE CIRCUIT BREAKER IS TURNED ON Putting the water heater into operation 1 With the circuit breaker off open the hot water valve until all air is purged 2...

Page 6: ...r flow to activate unit 0 76 0 92 gpm 2 9 3 5 l min 0 85 1 0 gpm 3 2 3 8 l min 0 92 1 1 gpm 3 2 4 0 l min 0 92 1 1 gpm 3 4 4 0 l min Minimum water pressure to activate unit 3 psi 0 2 bar 4 4 psi 0 3 bar 4 4 psi 0 3 bar 4 4 psi 0 3 bar Max working pressure 150 psi 10 bar Volume of water in unit 0 13 gal 0 5 l Weight 3 44 lb 1 56 kg Dimensions H x W x D 13 350 mm x 7 210 mm x 3 100 mm Plumbing conne...

Page 7: ...ue tradicionales de varias maneras Este calentador no almacena agua caliente Al con trario calienta el agua instantáneamente cuando esta fluye a través de la unidad El poderoso elemento que calienta el agua esta activado por su mecanismo de control de flujo solamente cuando se abre un grifo conectado al circuito de agua caliente de la casa sitio donde está instalado el DH El calentador DH ahorra e...

Page 8: ...l agua fría 6 Agujero para montaje inferior 7 Bloque de cableado 8 Agujero para montaje superior 9 Aro de refuerzo de goma para el cable 10 Tornillo fijado para la tapa plastica 11 Diagrama para el montaje fijación de tornillos 12 Diagrama para el montaje del equipo sobre la pared 13 Filtro malla de retención 14 Tuerca de unión con arandela suministrado por el instalador Leyenda ...

Page 9: ...l agua fría 6 Agujero para montaje inferior 7 Bloque de cableado 8 Agujero para montaje superior 9 Aro de refuerzo de goma para el cable 10 Tornillo fijado para la tapa plastica 11 Diagrama para el montaje fijación de tornillos 12 Diagrama para el montaje del equipo sobre la pared 13 Filtro malla de retención 14 Tuerca de unión con arandela suministrado por el instalador Leyenda ...

Page 10: ...ón locales y nacionales de instalaciones hidráulicas plomería 2 Es indispensable instalar una válvula reductora de presión si el agua alimentando el DH sobrepasa una presión mayor de 100 psi 60 bar 3 Antes de conectar la línea de agua fría a la unidad hay que purgar la tubería para asegurarse que no hay residuos o sucios en la misma 4 La conexión entrada del agua fría está en el lado derecho de la...

Page 11: ...mienda que se remueva periódicamente cualquier sucio o deposito que se pueda acumular en la salida de agua del grifo o en la cabeza de la ducha Modelo1 DH 60 DH 80 DH 100 DH 100 C Catálogo 227259 227329 234029 234030 Design Presurizado cerrado Corriente Monofásico 60 50 Hz 208 V 9 36 kW 45 A 220 V 5 5 kW 25 A 7 3 kW 33 A 8 4 kW 38 A not available 230 V 6 0 kW 26 A 8 0 kW 35 A 9 2 kW 40 A not avail...

Page 12: ... de agua es muy alto El control de temperatura está en una posición demasiado baja Girar la perilla de control de temperatura a la derecha hasta su posición máxima Identificar y resolver problemas Garantía ParalosaparatosadquiridosfueradelosEstadosUnidosnosonaplicableslascondicionesdegarantíadenuestrassociedades americanos Además en los países en los que alguna de nuestras filiales comercialice nu...

Page 13: ...Notes Notas ...

Page 14: ...ges Sous réserve d erreurs et de modifications techniques Salvo error o modificación técnica Distributed by Stiebel Eltron Inc 17 West Street West Hatfield MA 01088 Tel 800 582 2213 Fax 413 247 3369 info aptankless com www aptankless com ...

Reviews: