  THIS MANUAL MUST BE READ CAREFULLY BEFORE ATTEMPTING TO INSTALL THE AQUA POWER  
  WATER HEATER.  IF YOU DO NOT FOLLOW THE SAFETY RULES OR THE INSTRUCTIONS OUTLINED  
  IN THIS MANUAL, THE UNIT MAY NOT OPERATE PROPERLY AND IT COULD CAUSE PROPERTY DAM- 

  AGE, SERIOUS BODILY INJURY AND/OR DEATH.

  AQUA POWER WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE IN- 
  STALLATION AND OPERATING INSTRUCTIONS OUTLINED IN THIS MAN UAL OR BECAUSE OF IMPROPER  
  USE.  IMPROPER USE INCLUDES THE USE OF THIS APPLIANCE TO HEAT ANY LIQUID OTHER THAN WATER.   
  FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OR IMPROPER USE VOIDS  
  THE WARRANTY.  NEVER REMOVE THE UNIT’S COVER UNLESS THE ELECTRICITY IS TURNED OFF.

General

The Aqua Power DH series instantaneous water heater differs 
from conventional storage type water heaters in several ways.  
It does not store hot water.  Instead, water is heated instanta-
neously as it flows through the unit.  The powerful heating ele-
ments are activated by a flow switch as water is drawn from a 
hot water faucet connected to the DH unit.  Due to the absence 
of stand-by losses, the DH series has greater energy efficiency 
than storage type water heaters.

The temperature of the hot water delivered by the DH series is 
electronically controlled.  Set the temperature using the knob 
on the front cover.  In addition the outlet temperature can be 
controlled at the draw off point by varying the flow rate.  In 
order for the DH unit to operate properly, it must be carefully 
matched to the application.

The DH series can be used for whole apartments and homes 
in warm climate zones such as the Caribbean region, Central 
America and Mexico due to the higher ambient water tempera-
tures.

Summary of Contents for DH 100

Page 1: ......

Page 2: ...ntaneous water heater differs from conventional storage type water heaters in several ways It does not store hot water Instead water is heated instanta neously as it flows through the unit The powerful heating ele ments are activated by a flow switch as water is drawn from a hot water faucet connected to the DH unit Due to the absence of stand by losses the DH series has greater energy efficiency ...

Page 3: ...tion 5 Cold water connection 6 Lower mounting hole 7 Wiring block 8 Upper mounting hole 9 Rubber grommet for connection cable 10 Cover securing screw 11 Depth for mounting screw 12 Rear wall installation 13 Filter screen 14 Union nut and washer provided by installer Figure legend ...

Page 4: ...tion 5 Cold water connection 6 Lower mounting hole 7 Wiring block 8 Upper mounting hole 9 Rubber grommet for connection cable 10 Cover securing screw 11 Depth for mounting screw 12 Rear wall installation 13 Filter screen 14 Union nut and washer provided by installer Figure legend ...

Page 5: ...OUNTING AND PLUMBING MUST BE COMPLETED BE FORE PROCEEDING WITH ELECTRICAL HOOK UPS WARNING AS WITH ANY ELECTRIC APPLIANCE FAILURE TO ELECTRICALLY GROUND UNIT MAY RESULT IN SERIOUS INJURY OR DEATH THE UNIT S PLASTIC COVER MUST BE INSTALLED BEFORE THE CIRCUIT BREAKER IS TURNED ON Putting the water heater into operation 1 With the circuit breaker off open the hot water valve until all air is purged 2...

Page 6: ...r flow to activate unit 0 76 0 92 gpm 2 9 3 5 l min 0 85 1 0 gpm 3 2 3 8 l min 0 92 1 1 gpm 3 2 4 0 l min 0 92 1 1 gpm 3 4 4 0 l min Minimum water pressure to activate unit 3 psi 0 2 bar 4 4 psi 0 3 bar 4 4 psi 0 3 bar 4 4 psi 0 3 bar Max working pressure 150 psi 10 bar Volume of water in unit 0 13 gal 0 5 l Weight 3 44 lb 1 56 kg Dimensions H x W x D 13 350 mm x 7 210 mm x 3 100 mm Plumbing conne...

Page 7: ...ue tradicionales de varias maneras Este calentador no almacena agua caliente Al con trario calienta el agua instantáneamente cuando esta fluye a través de la unidad El poderoso elemento que calienta el agua esta activado por su mecanismo de control de flujo solamente cuando se abre un grifo conectado al circuito de agua caliente de la casa sitio donde está instalado el DH El calentador DH ahorra e...

Page 8: ...l agua fría 6 Agujero para montaje inferior 7 Bloque de cableado 8 Agujero para montaje superior 9 Aro de refuerzo de goma para el cable 10 Tornillo fijado para la tapa plastica 11 Diagrama para el montaje fijación de tornillos 12 Diagrama para el montaje del equipo sobre la pared 13 Filtro malla de retención 14 Tuerca de unión con arandela suministrado por el instalador Leyenda ...

Page 9: ...l agua fría 6 Agujero para montaje inferior 7 Bloque de cableado 8 Agujero para montaje superior 9 Aro de refuerzo de goma para el cable 10 Tornillo fijado para la tapa plastica 11 Diagrama para el montaje fijación de tornillos 12 Diagrama para el montaje del equipo sobre la pared 13 Filtro malla de retención 14 Tuerca de unión con arandela suministrado por el instalador Leyenda ...

Page 10: ...ón locales y nacionales de instalaciones hidráulicas plomería 2 Es indispensable instalar una válvula reductora de presión si el agua alimentando el DH sobrepasa una presión mayor de 100 psi 60 bar 3 Antes de conectar la línea de agua fría a la unidad hay que purgar la tubería para asegurarse que no hay residuos o sucios en la misma 4 La conexión entrada del agua fría está en el lado derecho de la...

Page 11: ...mienda que se remueva periódicamente cualquier sucio o deposito que se pueda acumular en la salida de agua del grifo o en la cabeza de la ducha Modelo1 DH 60 DH 80 DH 100 DH 100 C Catálogo 227259 227329 234029 234030 Design Presurizado cerrado Corriente Monofásico 60 50 Hz 208 V 9 36 kW 45 A 220 V 5 5 kW 25 A 7 3 kW 33 A 8 4 kW 38 A not available 230 V 6 0 kW 26 A 8 0 kW 35 A 9 2 kW 40 A not avail...

Page 12: ... de agua es muy alto El control de temperatura está en una posición demasiado baja Girar la perilla de control de temperatura a la derecha hasta su posición máxima Identificar y resolver problemas Garantía ParalosaparatosadquiridosfueradelosEstadosUnidosnosonaplicableslascondicionesdegarantíadenuestrassociedades americanos Además en los países en los que alguna de nuestras filiales comercialice nu...

Page 13: ...Notes Notas ...

Page 14: ...ges Sous réserve d erreurs et de modifications techniques Salvo error o modificación técnica Distributed by Stiebel Eltron Inc 17 West Street West Hatfield MA 01088 Tel 800 582 2213 Fax 413 247 3369 info aptankless com www aptankless com ...

Reviews: