Possible Causes/Solutions:
The “Low Pressure” indicator light is to inform you that your Aqua Phase may not be spraying
an adequate amount of water to achieve proper cleaning.
1. FILTER SCREEN(S) NOT CLEAN
•
Clean filter screen(s)
•
Clean Primary Filter Screen (Primary Filter Screen is located in the bottom of the
water reservoir, located inside of the Wash Chamber).
•
See also Making “Growling” Noise
2. DETECTIVE PRESSURE SENSOR.
•
Replace—you may order replacement parts by calling your dealer or the factory.
3. PUMP IMPELLER CLOGGED WITH DEBRIS
•
See
“Pump Impeller Inspection Procedures”
located in the
Servicing
Procedures Guide
section of your Aqua Phase’s operating manual. It is
recommended that you contact the factory before servicing the pump impeller.
"
LO
W
PRESSURE
INDICATOR
LIGHT/MESSAGE IS AL
W
A
Y
S ON