WARNING:
Unplug the machine from the power supply before
performing any service procedures.
It is recommended that you contact the factory at 800-208-9274 before attempting to clear debris from
the pump impeller. Removing debris from the pump impeller requires disassembly of the pump.
1.
Unplug
the
Aqua Phase
from the power supply.
2.
Disconnect the electrical wires at the pump.
3.
Disconnect the hose going to the inlet of the pump.
4.
Disconnect the hose or piping from the pump outlet.
5.
Remove the pump mounting bolts from the underside of the machine.
6.
The pump is composed of two components: the pump head and the pump motor.
•
You do not need to remove the pump head from the pump motor.
•
You do need to take the pump head apart.
7.
Remove the bolts holding the pump head together.
8.
You may need to tap (hit) the pump head assembly to free the two halves.
9.
Inspect the pump impeller.
•
Check the impeller housing and the inlet elbow for any obstructions, and remove debris if
necessary.
10.
Inspect the pump seal/gasket. Replace if damaged.
•
If your pump has an "O-Ring" seal, you may order a replacement from the factory.
11.
Reassemble and reinstall the pump.
Aqua Phase
, A Division Mid-State Stainless Inc. ●330 W Benson Ave. ●PO Box 228 ●Grantsburg, WI 54840 ●USA
800-208-9274 ●715-463-5851●FAX: 715-463-5853● Email:
●WEB:
www.aqua-phase.com
PUMP IMPELLER INSPECTION
PROCEDURES