Possible Causes/Solutions:
1. PRIMARY FILTER SCREEN DIRTY
•
Clean Primary Filter Screen (located in the Water Reservoir inside the Wash
Chamber).
2. SECONDARY FILTER SCREEN DIRTY
•
Clean Secondary Filter Screen (located in the Water Reservoir under the Primary
Filter Screen inside the Wash Chamber).
3.
KINK IN WATER DRAIN HOSE
•
Inspect water Drain Hose to ensure no shard bends in hose.
4.
DIRT, DEBRIS, OR HARD WATER DEPOSITS ON LOW-LEVEL FLOAT
SWITCH
•
Unplug the Aqua Phase from the power supply.
•
Locate the Low-Level Float Switch in the Water Reservoir, inside the Wash
Chamber.
**Inspect Float Switch to ensure that it is clear of debris and moves freely.
5.
DAMAGED OR DEFECTIVE LOW-LEVEL FLOAT SWITCH
•
Unplug the Aqua Phase from the power supply.
•
Inspect the Low-Level Float Switch for damage, such as a cracked fitting or
binding.
•
Replace if damaged—you may order replacement parts by calling your dealer or
the factory.
6.
DRAIN PUMP FUSE BLOWN.
•
Test fuse in Control Panel Assembly.
7.
FAULTY DRAIN PUMP
AQUA PHASE
W
ILL NOT
STOP DRAINING.
DRAINING TA
K
ES TOO LONG.
39