background image

https://aquacreekproducts.com/help-center/troubleshooting/

8/15/2022 12:41:43 PM PAGE - 8  

Aqua Creek Products Annual Pool Lift Safety

INSPECTION REPORT

LIFT / INSPECTION INFORMATION

Test Date:
Pool Lift Model:
Serial Number:
Inspected By:

Find additional trouble shooting info. and videos at: 

For Additional Support Assistance Call:

Toll Free: 888-687-3552

International: 1+406-549-0769

Maintenance Notes:

Please read and fill out 

all

 information carefully

Improper use and/or maintenance of pool lift can lead to actuator and/or other mechanical failures and 

possible personal injury.  Please read and follow the product operators' manual and the instructions 

below.     

NOTE: Completely cycle the lift 

without

 a load 

before each use

 to 

verify the lift is   functioning properly

.

Product service life depends on the load characteristics, type and frequency of use, and the environment in 

which the product is being used.  For example, persons not calmly sitting but falling down with their full body 
weight in the chair, or using the pool lift's chair as a diving platform can cause premature actuator failure 
and/or possible personal injury.
Based on historical product service life analysis, Aqua Creek recommends replacing the actuator(s) and other 

electronic components after 5 years of service. Check component serial numbers and purchase records to 
verify the age of your components.
A functional weight lifting force of a maximum of 100lbs. Must be periodically verified by applying a non-live 

load (without a person) through the entire operating cycle of the lift.  This process is performed in order to 
verify the smooth operation.  Make note of any unusual noises or sudden movements coming from the 
actuator(s) or other components.  Note: In some lifts, a sudden quick movement at the beginning of the 
cycle is normal but should smooth out over the course of operation.
Creating a side load on the actuator by pushing and/or pulling on the actuator, especially under load 

conditions, can cause damage to the actuator and or personal injury.
Electronic components are designed to be plug-and-play type replacements.  There is no need to access the 

internal mechanisms in these components.  The actuator, battery, and all electronic components may only be 
disassembled by authorized factory-trained personnel.  Disassembly of electronic components by improperly 
trained and unauthorized persons will void the warranty on those components.
The operator of the pool lift should never allow the pool lift to hit any stationary object either vertically or 

horizontally while operating a pool lift, i.e. walls, ceiling, pool/spa bench, etc.
For quick and accurate troubleshooting and inspections, we recommend having a voltage meter, Vito Battery 

Check Cable (Item F-VTC002) and an Aqua Creek Test Light (Item F-01TL) on hand as well as adequate test 
and replacement components for the unit.
Remove the pool lift from service immediately if any unusual noise is heard coming from the actuator such as 

grinding, popping or sudden inconsistent movements.
Immediately remove from service any lift that does not have 100% compliance with the inspection until the 

appropriate corrections have been made by a qualified person.

Summary of Contents for F-EZPL2

Page 1: ...PAGE 1 EZ2 CATALOG NO F EZPL2 READ CAREFULLY Check entire box and all packing materials for parts Before beginning assembly read the instructions and identify parts using the figures and parts listed...

Page 2: ...eck the unit periodically for signs of deterioration Keep all nuts bolts and screws tight to be sure the lift is in safe working condition Affix supplied ADA POOL SPA LIFT sign in a location visible f...

Page 3: ...HRU 09 7 EZ2 CATALOG NO F EZPL2 PAGE PAGE Aqua Creek Products TABLE OF CONTENTS 8 15 2022 12 41 43 PM PAGE 3 PRODUCT DOCUMENTS PRODUCT DOCUMENTS 1 COVER SHEET TABLE OF CONTENTS 3 IMPORTANT SAFETY INST...

Page 4: ...M EZ2 3 INV01395 1 P1 ACTUATOR KIT HYDRAULIC RAM EZ2 4 INV01397 1 P1 ASSEMBLY SWIVEL EZ SERIES 5 INV01394 1 P1 WELDMENT HANGER BAR EZ SERIES 6 INV01383 1 P1 ASSEMBLY CHAIN SET EZ SERIES 7 INV01386 1 P...

Page 5: ...OTE BE CAREFUL NOT TO OVERTIGHTEN BOLTS OVER TIGHTENING CAN CAUSE DAMAGE AND COMPROMISE THE SAFETY OF YOUR LIFT STEP 03 A STEP 03 B DETAIL STEP 03 A SCALE 1 3 WF 5 16 FLAT WASHER PART NO INV01176 NN 5...

Page 6: ...18 NYLOCK NUT PART NO INV00742 STEP 05 STEP 06 STEP 07 DETAIL STEP 05 SCALE 1 3 DETAIL STEP 06 SCALE 1 2 DETAIL STEP 07 SCALE 1 4 5 REMOVE THE HANGER BAR FROM THE SHIPPING BOX CONNECT THE HANGER BAR T...

Page 7: ...ASHER PART NO INV01170 9 WITH THE LIFT FULLY ASSEMBLED AND ANCHORED RUN THE LIFT COMPLETELY OUT AND BACK IN 3 TO 5 TIMES WITHOUT WEIGHT FOR THE LIFTS BREAK IN CYCLE PERIOD CONGRATULATIONS YOUR LIFT IS...

Page 8: ...t a person through the entire operating cycle of the lift This process is performed in order to verify the smooth operation Make note of any unusual noises or sudden movements coming from the actuator...

Page 9: ...components are clean corrosion free and in good 3 overall condition Clean and repair any missing powder coat finish Apply a coat of was on the cleaned and repaired finish Welded joints show no signs o...

Page 10: ...at least 90 degrees over the water and back again if 3 applicable A physical test of the lift function is required when doing an annual inspection NOTE The lift should always be run through a complete...

Page 11: ...the defect Within thirty 30 days after receipt of a written warranty claim by Aqua Creek and barring any unforeseen delays the place of purchase will be notified of Aqua Creek s decision regarding the...

Page 12: ...worn Replace as needed PROPER CARE NOTES Use only fresh water to wash your lift Do not wash with pool water Use only clean soft non abrasive cloths on your lift Do not store lift in pump room or near...

Reviews: