background image

NOTES/RECOMMENDATIONS:

With all connections connected, operate the lift through a 

1.

complete cycle without weight to confirm the lift is functioning 
correctly. Note any strange noises and any unusual operation.
Verify the lift was installed correctly; is the lift free to travel in and 

2.

out of the pool without hitting anything like a wall, rail, bench, 
etc…
Rotate lift at least 90 degrees over the water and back again if 

3.

applicable.

A physical test of the lift function is required when doing an annual inspection.  NOTE: The lift should 

always be run through a completed cycle without a load prior to each use.  The annual test should be 

ran both empty and with a typical load weight to test the lift's functions.  Make comments and/or 

recommendations in the notes area below each section.

N/A

FAIL

PASS

INSPECTION ITEM

1. PHYSICAL POOL LIFT TEST

Aqua Creek Products Annual Pool Lift Safety

INSPECTION REPORT

8/15/2022 12:41:43 PM PAGE - 10  

Summary of Contents for F-EZPL2

Page 1: ...PAGE 1 EZ2 CATALOG NO F EZPL2 READ CAREFULLY Check entire box and all packing materials for parts Before beginning assembly read the instructions and identify parts using the figures and parts listed...

Page 2: ...eck the unit periodically for signs of deterioration Keep all nuts bolts and screws tight to be sure the lift is in safe working condition Affix supplied ADA POOL SPA LIFT sign in a location visible f...

Page 3: ...HRU 09 7 EZ2 CATALOG NO F EZPL2 PAGE PAGE Aqua Creek Products TABLE OF CONTENTS 8 15 2022 12 41 43 PM PAGE 3 PRODUCT DOCUMENTS PRODUCT DOCUMENTS 1 COVER SHEET TABLE OF CONTENTS 3 IMPORTANT SAFETY INST...

Page 4: ...M EZ2 3 INV01395 1 P1 ACTUATOR KIT HYDRAULIC RAM EZ2 4 INV01397 1 P1 ASSEMBLY SWIVEL EZ SERIES 5 INV01394 1 P1 WELDMENT HANGER BAR EZ SERIES 6 INV01383 1 P1 ASSEMBLY CHAIN SET EZ SERIES 7 INV01386 1 P...

Page 5: ...OTE BE CAREFUL NOT TO OVERTIGHTEN BOLTS OVER TIGHTENING CAN CAUSE DAMAGE AND COMPROMISE THE SAFETY OF YOUR LIFT STEP 03 A STEP 03 B DETAIL STEP 03 A SCALE 1 3 WF 5 16 FLAT WASHER PART NO INV01176 NN 5...

Page 6: ...18 NYLOCK NUT PART NO INV00742 STEP 05 STEP 06 STEP 07 DETAIL STEP 05 SCALE 1 3 DETAIL STEP 06 SCALE 1 2 DETAIL STEP 07 SCALE 1 4 5 REMOVE THE HANGER BAR FROM THE SHIPPING BOX CONNECT THE HANGER BAR T...

Page 7: ...ASHER PART NO INV01170 9 WITH THE LIFT FULLY ASSEMBLED AND ANCHORED RUN THE LIFT COMPLETELY OUT AND BACK IN 3 TO 5 TIMES WITHOUT WEIGHT FOR THE LIFTS BREAK IN CYCLE PERIOD CONGRATULATIONS YOUR LIFT IS...

Page 8: ...t a person through the entire operating cycle of the lift This process is performed in order to verify the smooth operation Make note of any unusual noises or sudden movements coming from the actuator...

Page 9: ...components are clean corrosion free and in good 3 overall condition Clean and repair any missing powder coat finish Apply a coat of was on the cleaned and repaired finish Welded joints show no signs o...

Page 10: ...at least 90 degrees over the water and back again if 3 applicable A physical test of the lift function is required when doing an annual inspection NOTE The lift should always be run through a complete...

Page 11: ...the defect Within thirty 30 days after receipt of a written warranty claim by Aqua Creek and barring any unforeseen delays the place of purchase will be notified of Aqua Creek s decision regarding the...

Page 12: ...worn Replace as needed PROPER CARE NOTES Use only fresh water to wash your lift Do not wash with pool water Use only clean soft non abrasive cloths on your lift Do not store lift in pump room or near...