AQC MAXAIR Manual Download Page 23

Fume Arms

23

  15   WARRANTY

 15.1 

Coverage: 

Aireau Quality Control Inc. or its designated affiliate (the "Seller") selling the product 

(the "Product"), warrants that the Product sold by Seller will be free from defects in material and 

workmanship for a period of 12 months from the date of its installation or 14 months from the 

date of shipment by Seller, whichever date is earlier (the "Warranty Period"). 

 15.2 

Exceptions: 

This warranty does not apply to any Product or portion thereof that: (i) has been used 

in a manner not in compliance with Seller’s or manufacturer’s documentation and instructions, (ii) 

has had changes, alterations or repairs made by a person other than a person authorized by Seller, 

(iii) has been improperly installed or used or has been installed or used contrary to applicable 

codes, standards, laws and regulations, (iv) has been subjected to improper storage, accident, 

neglect, misuse or abuse, (v) has been damaged during shipping,  (vi) has been subject to damages 

resulting from normal wear and tear, (vii) has not been used with appropriate fire protection 

systems or explosion venting when required or (viii) has not been installed by a licensed contractor 

with experience in fire and explosion hazards and applicable codes, laws and regulations . For 

greater certainty, this warranty does not apply to filters sold as part of, or for use with, the Product. 

Unless specifically accepted otherwise in writing by Seller, Seller does not warrant that electrical 

equipment will comply with any laws or regulations of the customer’s jurisdiction. 

 15.3 

Claims: 

To benefit from this warranty, customer must notify Seller in writing of the Product defect, 

which notice shall include a reasonable description of the defect, within 10 days from the date such 

defect is discovered or ought to have been discovered.

 15.4 

Remedy: 

During the Warranty Period and subject to the terms herein, Seller will, at its option, 

either: (i) repair or replace the Product or any defective parts or components (except for filters) 

with Product, parts or components (except filters) free from defect or (ii) credit or refund the 

purchase price of the Product. If Seller so requests, customer must return the defective Product to 

Seller’s place of business determined by Seller. Shipping, installation, removal and re-installation 

costs will be solely borne by the customer. 

The foregoing shall be customer’s sole and exclusive 

remedy for any defect in the product, its parts and components and for any breach of the 

warranty herein.

 15.5 

Disclaimer:

 

Except as set forth in this section 1, each of seller, its affiliates and their directors, 

officers, subcontractors and representatives (the "seller parties") disclaims all representations 

and warranties, whether written, oral, express, implied, statutory, or otherwise, including 

all  implied  warranties  of  merchantability,  quality,  fitness  for  a  particular  purpose,  non-

infringement, and warranties arising from a course of dealing, course of performance, usage, 

or trade practice and customer hereby expressly waives any right related thereto. Without 

limitation to the foregoing and except as expressly set out herein, the seller parties do not 

represent or warrant that: (a) the use of the product will be timely, uninterrupted or operate 

in combination with any other hardware, software, system or data or (b) the product will meet 

customer’s intended use, requirements or expectations. 

Summary of Contents for MAXAIR

Page 1: ...tion use and maintenance This manual is property of the owner Leave with the unit when set up and start up are complete AQC Dust Collecting Systems inc reserves the right to change design and specific...

Page 2: ...racket installation hanging type no exhaust fan 11 8 4 Arm and ceiling bracket installation hanging type 13 8 5 Arm and bracket installation hanging type with exhaust fan 14 9 Optional equipment 15 9...

Page 3: ...nnel using the system should be trained on safety measures and maintenance instructions 2 INFORMATION ON THE MAXAIR FUME ARM Model Serial number Delivery date Date of installation Name of customer Add...

Page 4: ...include a direct drive fan extension swing boom for additional reach sliding rail with trolley etc 3 1 Each MAXAIR unit includes External and adjustable joints Painted steel or stainless steel tubes...

Page 5: ...05 FA PPG4 05 FA HSS4 05 FA PSS4 05 4 102 5 1 5 8 203 17 7 7 FA HPG4 07 FA PPG4 07 FA HSS4 07 FA PSS4 07 4 102 7 2 1 8 203 19 8 6 FA HPG4 08 FA PPG4 08 FA HSS4 08 FA PSS4 08 4 102 8 5 2 4 8 203 22 10...

Page 6: ...SE During normal operation the MAXAIR fume arm is pulled or pushed into position near the source of pollutants 8 to 16 from the source The hood tube grab handle on 5 6 and 8 arms only may be used for...

Page 7: ...ersion 1 Socket set assembly 2 Flexible hose typ of 3 3 Socket tube 4 Hood tube 5 Damper handle 6 Connectors for hood movement typ of 4 7 Joint wheel 8 Capture hood 9 Hood grab handle 10 Articulating...

Page 8: ...portable version 1 Socket set assembly 2 Flexible hose typ of 3 3 Socket tube 4 Hood tube 5 Damper handle 6 Connectors for hood movement typ of 4 7 Joint wheel 8 Capture hood 9 Hood grab handle 10 Art...

Page 9: ...ble hose typ of 2 3 Socket tube fixed 4 Hood tube sliding twist and lock 5 Damper handle 6 Connectors for hood movement typ of 4 7 Joint wheel 8 Hood grab handle 9 Articulating joints typ of 4 10 Tele...

Page 10: ...d with shipment Inspect box or crate appearance when receiving the goods Report damages to carrier immediately Failure to do so will void future claims Note Because of sizes and dimensions optional ov...

Page 11: ...step 4 is completed 1 Install bracket on support structure at proper height for arm length Fasteners to support structure are not supplied Arm bracket can also be welded to structure if allowed or pe...

Page 12: ...ds it s position and does not sag Proceed with left and right middle joints End with all four 4 adjustable joints at hood section 7 Move arm UP DOWN LEFT RIGHT to ensure arm stays in position 8 Procee...

Page 13: ...nging type installation procedures 8 5 Arm and bracket installation hanging type with exhaust fan Note This type of installation will not require the duct flange The installation crew must ensure the...

Page 14: ...exhaust air Place fan onto arm support bracket Align fan inlet flange bolt holes to bolt pattern on arm bracket Secure fan temporarily to support bracket using C clamps Proceed with steps 3 to 7 in a...

Page 15: ...not force arm down at socket past the maximum bend This may cause damages in the spring and cable assembly in socket 9 1 1 Mounting The capture arm can be mounted on a wall Ensure the wall is level a...

Page 16: ...l be required if bracket and arm are not of same diameters ex 1 hp 6 fan inlet with 5 diameter fume arm MAXAIR hanging model wall or post with exhaust fan and support bracket MAXAIR hanging model with...

Page 17: ...et e 6 2 Boulon 0 25 x 0 75 7 1 Support de ressort de douille 2 trous MAXAIR hanging model wall or post with exhaust fan and support bracket MAXAIR hanging model wall or post with exhaust fan and supp...

Page 18: ...ds and listen for grinding or unusual noise If fan runs smoothly you may start using the system Refer to MAXIDRIVE instruction manual if you need instructions 11 LIGHT KIT PARTS LIST AND INSTALLATION...

Page 19: ...ECTRICIAN WIRING CF ORANGE CF YELLOW RED OL BROWN MTR1 OPTION CLASS 2 OPTION SXX OPTION FXX Adjust according to the table 1 VOLT Adjust according to the table 1 VOLT Adjust according to the table 1 OL...

Page 20: ...e table 1 VOLT OPTION SXX OPTION FXX Adjust according to the table 1 OL Adjust according to the table 2 or 3 X1 X2 H1 H2 40VA 2 1 3 4 6 24VAC 5 U1 V1 L1 L2 Westburne Laval 3409 Boul Industriel 450 663...

Page 21: ...r source capture Open and close air damper to ensure proper operation Move arm left and right Ensure no grinding or squeeking is heard or felt Weekly Flexible hoses Check for possible leaks or tears R...

Page 22: ...bes for debris Open ductwork and check for debris Socket grinds squeaks jams Foreign object in socket Inspect complete socket assembly 24V LED light blinks Screws holding the bulb or bulb wiring in pl...

Page 23: ...omer must notify Seller in writing of the Product defect which notice shall include a reasonable description of the defect within 10 days from the date such defect is discovered or ought to have been...

Page 24: ...ty of such damages or could have reasonably foreseen them 16 3 Fire and Explosion and Acceptance of Risk Customer acknowledges that improper installation or use of the Product may result in fire or ex...

Reviews: