Fume Arms
13
8.4 Arm and ceiling bracket installation (hanging type)
The installation crew must ensure the arm/bracket assembly is installed within the arm reach for
the area where source capture has to be performed. The arm bracket must be installed to ceiling
trusses or joists or any other structure capable of supporting weight of the arm and optional
equipment.
1.
Install bracket on support structure according to arm length. Fasteners to support structure
are not supplied. Arm bracket can also be welded to structure if allowed or permitted.
Proceed with steps 3 to 7 in arm hanging type installation procedures.
8.5 Arm and bracket installation (hanging type with exhaust fan)
Note :
This type of installation will not require the duct flange.
The installation crew must ensure the arm/bracket assembly is installed within the arm reach of
the area where source capture has to be performed. The arm bracket must be installed on a wall,
post or any other structure capable of supporting weight of the arm and optional equipment.
Note on arms equipped with recoil telescopic springs :
Do not attach spring assembly from socket
tube spring bracket to rotating socket.
WARNING!
The electrical connection must be performed by a qualified
electrician and with respect to codes and regulations.
For safety measures, shut off power supply to the motor
prior to perform repairs.