43
9.3
WARNINGS - TC "AUTO" MODE
Warnings when the implement is in the Task Controller AUTO mode:
Display
Cause
Solutions
TC units inconsistent!
The units for the specified
values from the Task Controller
do not match the expected
units.
TC units must be verified.
TC specifications no longer
available!
The TC specification is no
longer available on the tractor
side.
Check the Task Controller.
TC specifications will be used!
The TC specification will be
used, it only serves as
information.
9.4
ERRORS
Display
Cause
Solutions
Operating voltage not OK!
The supply voltage is below
8 V.
Excessive voltage
fluctuations.
Minimise consumers (e.g.
switch off the work
floodlights).
Check the battery.
Check the cabling.
Check the plugs.
check the alternator.
Motor is overloaded (seeding
shaft I)!
Motor is overloaded (seeding
shaft II)!
A seed shaft is not able to
rotate.
The motor has been
strained too long at its
limits!
Switch off the control box!
Remove any foreign objects
or similar from the seeding
shaft or the agitator.
Switch off the agitator (with
well-flowing seed).
Remove 1-3 spacing discs
from the seeding shaft.
Check the set motor type.
Check the idling motor for
proper function.
Refer to the seeder
operating manual
Error (fan)!
Only with electric fan:
Is displayed when the
implement cable is not
connected or the cabling is
faulty.
Check the cabling.
Check the plug on the
motor module.
Read the error message on
the motor module (motor
overloaded or motor not
connected) and fix the error
according to the seeder
operating manual.
Summary of Contents for ISOBUS M2
Page 54: ...54 NOTES ...
Page 55: ...55 NOTES ...