Technical data
Machine data
Honda, manual start
RP 160
Engine
Honda GX160 4-stroke
Type
4.1 (5.7)
Power, kW (hp)
3,600
Rated speed, r.p.m.
Performance
22 (72)
Operating speed, m/min (feet/min)
20 (35%)
Maximum tilt, °
Compaction data
80 (4,800)
Vibration frequency, Hz (r.p.m.)
28 (6.3)
Centrifugal force, kN (lbf)
1.4 (0.054)
Amplitude, mm (in.)
Fluid volumes
3.6 (3.8)
Fuel tank, litres (qts)
0.6 (0.63)
Crankcase oil capacity, litres (qts)
1 (1.1)
Hydraulic fluid, litres (qts)
0.4 (0.42)
Eccentric element, litres (qts)
0.95 (0.25)
Fuel consumption litres/hours (qts/h)
Lubricants
Shell Rimula R4 L 15W-40
Engine oil
Shell Rimula R4 L 15W-40
Eccentric element oil
Shell Tellus TX32
Hydraulic fluid
Shell Naturelle HF-X46
Biological hydraulic fluid
Use normal grade petrol.
Fuel
1.35 (1.43)
Fuel consumption, litres/hour (qts/h)
Weights
160 (353)
Net weight, kg (lb)
161 (355)
Operating weight EN500, kg (lb)
Noise and vibration declaration statement
Guaranteed sound power level
Lw
according to EN ISO 3744 in accordance with directive 2000/14/EC.
Sound pressure level
Lp
according to EN ISO 11201, EN 500-4:2011.
Vibration value determined according to EN 500-4:2011. See table ”Noise and vibration data” for the values
etc.
These declared values were obtained by laboratory type testing in accordance with the stated directive or
standards and are suitable for comparison with the declared values of other machines tested in accordance
with the same directive or standards. These declared values are not suitable for use in risk assessments and
values measured in individual work places may be higher. The actual exposure values and risk of harm
experienced by an individual user are unique and depend upon the way the user works, in what material the
machine is used, as well as upon the exposure time and the physical condition of the user, and the condition
of the machine.
We, Construction Tools EOOD, cannot be held liable for the consequences of using the declared values, instead
of values reflecting the actual exposure, in an individual risk assessment in a work place situation over which
we have no control.
This machine may cause hand-arm vibration syndrome if its use is not adequately managed. An EU guide to
managing hand-arm vibration can be found at http://www.humanvibration.com/humanvibration/EU/VIBGUIDE.html
25
© 2014 Construction Tools EOOD | No. 9800 1624 01 | 2014-06-19
Original instructions
Safety and operating instructions
RP 160