Checking the shock absorbers
1. Check all the shock absorbers (A) for cracks or
if they are exhausted. There are two shock
absorbers (A) on each side of the machine.
A
2. Change the shock absorbers (A) if they are
damaged.
Every 250 hours of operation
(every month)
Maintenance routines:
♦
Clean and refit the air filter. See the engine manual
for more information.
♦
Check and adjust engine valve clearances. See
the engine manual for more information.
♦
Clean the fuel tank and fuel filter. See the engine
manual for more information.
♦
Change the engine oil. See the engine manual for
more information.
♦
Clean the engine's cooling flanges.
♦
Clean the engine's exhaust pipe. See the engine
manual for more information.
♦
Check and tighten screws and nuts.
♦
Lubricate controls and links.
♦
Check all rubber elements.
♦
Check the hydraulic fluid.
Checking bolted joint
Check and if necessary tighten screws and nuts.
Hydraulic system, checking the hydraulic oil
level
1. Check the hydraulic oil level by using the dipstick
(A).
2. Fill up with hydraulic oil if necessary, see chapter
"Hydraulic system, changing the hydraulic oil".
Every 500 hours of operation
(yearly)
Maintenance routines:
♦
Adjust valve clearance for intake and exhaust
valves. See the engine manual for more
information.
♦
Clean and check fuel filter and tank. See the
engine manual for more information.
♦
Refit the air filter.
♦
Changing the oil in the eccentric element. Only for
oil lubricated eccentric elements.
♦
Clean the engine's cooling flanges. See the engine
manual for more information.
♦
Clean and adjust the carburettor. See the engine
manual for more information.
23
© 2014 Construction Tools EOOD | No. 9800 1624 01 | 2014-06-19
Original instructions
Safety and operating instructions
RP 160