ECU-C Installation/User Manual
22
5.EMA Manager
For three-phase Microinverter: Please refer to the document
Altenergy_Power_System_Inc.___three_phase_microinverter_11-12.xlsx
on SunSpec website.
https://certifications.sunspec.org/PICS/Altenergy_Power_System_Inc.
___three_phase_microinverter_11-12.xlsx
For single-phase Microinverter: Please refer to the document
Altenergy_Power_System_Inc.___single_phase_MicroinverterAPpcs_11
-12 on SunSpec website.
https://certifications.sunspec.org/PICS/Altenergy_Power_System_Inc.
___single_phase_MicroinverterAPpcs_11-12.xlsx
Click Modbus Settings in the Workspace, switch on the SunSpec
Modbus function. Select the baud rate and configure Inverters
’
address in the address text box. Finally, click Save to finish
configuration.
The host
’
s RS485 port must be configured to the same baud rate, 8
data bits, 1 stop bit, none parity bit.
Not compatible with split-phase (2 phases) systems as commonly
used in the Americas.
5.EMA Manager