LAST Results screen will only display the last executed test step settings and
results at the end of a test.
Press the Change soft key to select the desired Results display mode. To save the setting,
press the “
Enter
” soft key. To cancel the editing, press the “
Esc
” soft key. When the “
Enter
”
soft key is pressed the
Results
display mode is accepted and you transition into the next
system parameter.
6.10.10
Over Current Fold Mode Settings
Press the “
Next
” soft key if needed to advance to the next parameter, the
OC Fold
setting.
Use the “
Change
” soft key to select from the following available OC Fold mode settings:
•
ON
In this mode, the voltage will be decreased as needed once the load current
reaches the set current limit value in order to keep the load current below
this current level. This limits the current to EUT to the max. value set by the
user.
•
OFF
In this mode, the output will trip off as soon as the load current exceeds the
programmed current limit value to protect the EUT from over current.
Press the Change soft key to select the desired OC Fold mode. To save the setting, press the
“
Enter
” soft key. To cancel the editing, press the “
Esc
” soft key. When the “
Enter
” soft key
is pressed the
OC Fold
mode is accepted and you transition into the next system parameter.
6.10.11
Keyboard Lock Mode Settings
Press the “
Next
” soft key if needed to advance to the next parameter, the
Lock
setting.
Note:
If a password has been set, a password entry dialog box will appear and the correct
password must be entered to change this setting. See Section 0, “