![APS CFS300 Series Operation Manual Download Page 45](http://html1.mh-extra.com/html/aps/cfs300-series/cfs300-series_operation-manual_2956871045.webp)
CFS300 SERIES OPERATION MANUAL
SECTION 5: UNPACKING & INSTALLATION
Entire Contents Copyright
2016 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CFS300 Series Power Source Operation Manual
Page 45 of 156
5.8.3
Available CFS360 AC Input Configurations
The CFS360 has three separate AC inputs, one for each of the three output phases. This
allows several AC input configuration to be set using the provided shorting bars. The
supported configurations are shown in the figure below.
PCF 1
PCF 2
PCF 3
AC1 IN
AC2 IN
AC3 IN
MODEL CFS360
UTILITY POWER CONFIGURATIONS
230V SINGLE
PHASE
1P2W+G
208V THREE
PHASE DELTA
3P3W+G
400V THREE
PHASE WYE
3P4W+G
L
L
L
G
N
N
N
A B C
L1
L2
L3
G
N1
N3
N
N2
A B C
L1
L2
L3
G
N1
N2
N3
AC
L
N
L1
L2
L3
N1
N2
N3
AC
L N
N
L
L N
A
B
C
AC
L1
L2
L3
A
B
C
A
B
C
N
Figure 6-7: Available CFS360 AC Input Configurations
5.8.4
AC Input Shorting Bars for CFS360
The following shorting bars and mounting screw required to configure the AC input
terminals by configuration are provided in the CFS360 ship kit.
Sorting Bar No:
1P2W
3P3W
3P4W
39177
-
3
-
39178
1
-
1
39179
1
-
-
Screw No:
1P2W
3P3W
3P4W
39243
2
-
1
Table 6-3: AC Input Shorting Bar Configurations