25
-
SWING APRICODE 230
CONTROL UNIT
English
parameters
FUNCTION
..................................
DEFAULT
SETTINGS
LO
Logic ...........................................AUTOMATIC
0 =
AUTOMATIC
; 4
=
STEP
-
BY
-
STEP
; 1
=
FOUR
STEPS
;
5 =
MANNED
; 2
=
SUPER
AUTOMATIC
; 6
=
TIMER
(
START
INPUT
)
3 =
SEMI
AUTOMATIC
WITH
STOP
;
PA
Pause time.....................................
25
sec.
0 ÷ 60 (1
SECOND
STEPS
)
ELS
.
Electric lock .............................................DISABLED
IF
CONNECTED
ENABLED
AUTOMATICALLY
FOLLOWING
SELF
-
TEACH
PROCEDURE
0 =
DISABLED
1 =
ENABLED
LAm
.
Pre-
fl
ashing time ...............................
3
sec.
1 ÷ 9 (1-
SECOND
STEPS
)
tA
.
Additional time at end of movement ..
6
sec.
3 ÷ 20 (1-
SECOND
STEPS
) -
ADDITIONAL
THRUST
IS
AT
REDUCED
SPEED
IF
ELECTRONIC
SLOWING
IS
USED
(
rEl
)
t1
.
Additional time after reverse .............
6
sec.
3 ÷ 20 (1-
SECOND
STEPS
)
nM
Number of wings ...............
automatically detected
0 =
AUTOMATICALLY
DETECTED
; 1 =
SINGLE
WING
; 2 =
DOUBLE
WING
d1
. ;
d2
.
Direction wing 1 .....................................
0
Direction wing 2 .....................................
0
0 ; 1
Mod
.
Operator type ................................ HYDRAULIC
0 =
HYDRAULIC
(
NOT
E1
-
E2
); 1
=
ELECTRO
-
MECHANICAL
E1
.
E2
.
Power wing 1 .......................................MAX
Power wing 2 .......................................MAX
(
ONLY
ELECTRO
-
MECHANICAL
OPERATORS
)
THRUST
FORCE
ELECTRONIC
ADJUSTMENT
:
0 (
MINIMUM
) ÷ 50 (
MAX
)
rEL
.
Electronic slowing............................ ENABLED
0 (
DISABLED
) ; 1 (
ENABLED
)
PSET
.
Restore factory settings (default)
RED
TO
CONFIRM
man
.
Access MAINTENANCE menu
RED
T
o
CONFIRM
RadI
Access MEMORIES menu
RED
T
o
CONFIRM
Prof
Access ADVANCED programming
RED
T
o
CONFIRM
A1
Wing 1 closing delay ...........................
5
SDgr
0 ÷ 15 (1
STEP
= 5°
OF
DISPLACEMENT
)
A2
Wing 2 opening delay .........................
2
SDgr
0 ÷ 5 (1
STEP
= 2,5°
OF
DISPLACEMENT
)
A3
Pedestrian opening ..........................DISABLED
0= 20%; 1= 40%; 2= 60%; 3=80%; 4= 100%
A4
Electric lock actuation time ...................
3
.
5
sec.
3 ÷ 6 (0.5-
SECOND
STEPS
)
A5
Electric lock advance .........................
0
.
5
sec.
0 ÷ 1 (0.5-
SECOND
STEPS
)
A6
Reverse stroke time .........................DISABLED
IF
ELECTRIC
LOCK
CONNECTED
.....................
0
.
5
sec.
0 ÷ 2 (0.5-
SECOND
STEPS
)
Reverse stroke: opening preceded by brief operation in the
reverse direction to facilitate release of the electric lock.
A7
Maximum torque time following startup ..
1
sec.
0 ÷ 3 (0.5-
SECOND
STEPS
)
(only electro-mechanical)
A8
Reverse time at end of closing ...........
0
sec.
0=0; 1=30; 2=50; 3=80; 4=100; 5=120; 6=150; 7=200; 8=300; 9=400 (
MSEC
.)
At the end of closing the motors are operated in reverse direction for the
time set to discharge the mechanisms when movement is complete.
A9
Approach speed ...................................
30
%
1= 30% ; 2= 40% (%
OF
MOVEMENT
SPEED
)
rat
Factory setting - Do NOT modify
0 ÷ 2 -
DO
NOT
MODIFY
LUM
Display luminosity .............................. MEDIUM
0 ÷ 9
Ad
Closing when photocell
uncovered ..............................
reloads pause time
00=
IMMEDIATELY
; 01=
AT
THE
END
OF
PAUSE
TIME
(
COUNTING
CONTINUES
)
; 02=
AFTER
10
SEC
. ; 03=
AFTER
A
NEW
COMPLETE
PAUSE
TIME
(
RELOADS
THE
PAUSE
TIME
)
Ae
Auxiliary output ........................... WARNING LIGHT
0 =
WARNING
LIGHT
; 1÷60 =
MINUTES
COURTESY
LIGHT
ON
AFTER
START
OR
PEDESTRIAN
START
NOTE
: only if not set on remote control
AH
Flashing light during pause ...................OFF
0=
OFF
; 1=
ON
(
IN
AUTOMATIC
MODE
)
AM
100%
fi
nal thrust time.....................DISABLED
If electric lock connected ...................
1
sec.
0 ÷ 5 (
DURING
CLOSING
FOR
ELECTRIC
LOCK
ENGAGE
)
Ar
.
Aux. opening safety device .......with PHOTOCELL
0=
SAFETY
EDGE
; 1=
PHOTOCELL
tf
.
Closing photocell test .....................DISABLED
0 =
DISABLED
; 1 =
STANDARD
PHOTOCELL
TEST
; 2 =
REFLEX
PHOTOCELL
TEST
An
.
Aux. opening safety device test ....DISABLED
0 =
DISABLED
; 1 =
STANDARD
PHOTOCELL
OR
EDGE
TEST
;
2 =
REFLEX
PHOTOCELL
OR
EDGE
TEST
AL
.
t
Movement Total counter (cannot be modi
fi
ed)
0000 ÷ 9999 (
INCREASES
BY
1
FOR
EVERY
100
MOVEMENTS
)
AL
.
P
Movement Partial counter for maintenance
0000 ÷ 9999 (1 = 10
MOVEMENTS
) (
RESET
USING
AL
.
S
OR
AL
.
r
)
AL
.
S
Sets maintenance cycle on
AL
.
P
0000 ÷ 9999 (1 = 10
MOVEMENTS
)
WITH
MINIMUM
STEP
100
MOVEMENTS
-
EACH
SETTING
ZERO
-
SETS
THE
COUNTER
AL
.
P
aL
.
r
Zero-sets the counter
AL
.
P
RED
TO
CONFIRM
Open
Saving the remote controls on the
built-in receiver Apricode ...........
open the memory
RED
TO
CONFIRM
(
THE
DISPLAY
SHOWS
seed
FOR
15
SEC
.)
rn
.
Deleting a remote control with address
0 ÷ 99
(see Programming remote controls)
r
.
tr
Deleting all remote controls
RED
TO
CONFIRM
UPLd
Saving control unit data on Plug-in memory module
RED
TO
CONFIRM
- (
OPTIONAL
PLUG
-
IN
MEMORY
MODULE
)
dnLd
Saving data from Plug-in memory module on control unit
RED
TO
CONFIRM
- (
OPTIONAL
PLUG
-
IN
MEMORY
MODULE
)
ch1
ch2
ch3
ch4
Remote control Output channel setting
ch1
................................................. START
ch2
..................................... PEDESTRIAN START
ch3
;
ch4
......................................... DISABLED
0 =
DISABLED
; 1
=
START
; 2
=
PEDESTRIAN
START
; 3 =
STOP
;
4 =
AUXILIARY
OUTPUT
USING
EXTERNAL
RELAIS
(2 sec. pulse if
Ae
=
0
;
timer 1÷60 if
Ae
=
1÷60
)