24
-
English
SWING APRICODE 230
CONTROL UNIT
T
4.3
esting on the display
To switch ON the display, press the
•
YELLOW
button once
quickly. To switch OFF the display, press the
YELLOW
button once quickly.
display 1
: GATE STATUS
C
= CLOSED
b
= OPENING
A
= OPEN
d
= CLOSED
E
= LOCKED
8
2
4
5
6
7
display 2
: INPUTS
(on=contact closed)
2 = CLOSING PHOTOCELL
4 = PEDESTRIAN START
5 = SAFETY DEVICE during OPENING
6 = START
7 = STOP
8
1
2
3
4
6
display 4
: OUTPUTS
(on=output active)
1 = FLASHING
2 = ELECTRIC LOCK
3 = WARNING LIGHT
4 = WING 2 MOTOR
6 = WING 1 MOTOR
IMPORTANT:
BLUE
To select
RED
To con
fi
rm
YELLOW
To exit
Inputs and outputs
4.2
•
START
(using button with N.O. contact or remote control) - starts the automation (opening or closing) on the basis of the
current state and the operating logic settings.
•
STOP
(button with N.C. contact) - the input stops the wing immediately. A
START pulse is required to continue movement.
The STOP input has priority over all other functions at all times.
•
Closing photocells
- these photocells are only enabled on the closing stroke. When triggered they will stop the movement
for 1 second and then start to reopen the gate.
These photocells will prevent closing as long as they are covered.
•
Auxiliary safety edge operating on opening stroke
- this is a safety input enabled during the opening stroke. The
safety edge will trigger if it touches an obstruction during the opening stroke. The wings will reverse for a short distance
and then stop. To complete the movement which has been interrupted in this way, you must press START. This will complete
the movement in safe mode, i.e. at slow speed with the warning light permanently lit.
•
Auxiliary opening safety photocells
- these photocells detect obstacles on the opening and closing strokes; they will
trigger on detecting an obstruction and stop the wings. The movement will only restart when the photocells are uncovered.
After a pause of 1 second, the movement will restart in the original direction.
•
Flashing light
- to signal the status of the automation: •
fl
ashing every 1 sec. normal functioning; • light ON operation
under safe conditions; •
fl
ashing every 0.5 sec. routine maintenance required.
If the fl ashing light is not used then the
pre-fl ashing function must be disabled (
lam
) by setting it to 0 seconds.
•
Warning light
- this is a remote signal indicating the current status of the operator: • light OFF gate closed; • light ON
gate open or opening; • light
fl
ashing gate closing.
/Auxiliary output using external relay
depending on (
ae
) parameter:
2 sec pulse type with activation by remote control (
ch1
-
4
) (ex: pedestrian gate electric lock actuation) OR timer (ex: lighting).
•
Courtesy light
- ON when START or PEDESTRIAN START is pressed, with programmable timer (
ae
).
Error codes and Warnings
4.3.1
when
•
Init
appears press the
YELLOW
and
BLUE
simultaneously for approx. 3 seconds.
Lrn
fl
ashes on display press
START
Routine maintenance is required if
•
MAN
fl
ashes for approximately 3 seconds when programming is accessed.
ERRORS:
•
Er0
= access to both memories;
Er1
= access to plug-in memory module;
Er2
= photocell test;
Er3
= safety edge test.
PROGRAMMING
5.
IMPORTANT! The gate must be stopped and closed before you can start programming.
WARNING: All input signals will be ignored during programming.
Press and hold
RED button
the display shows
PROC
Release the
RED button
displays the
fi
rst parameter with the value set
LO
.
0
BLUE
scrolls through the parameters
MODIFICA
TIONS to
SETTINGS
RED
when a parameter shown
shows the value set
(marked by the bullet)
pressing the
BLUE button
scrolls through the values
Press and hold the
RED
button for 3 seconds
to select a new value
3
fl
ashes con
fi
rm the modi
fi
cation
Release the
RED button
the new setting is displayed
YELLOW
returns to the parameters
The parameter has now been modi
fi
ed. More modi
fi
cations can be made before you exit the programming function.
WARNING:
modifi cations are only confi rmed when you exit the programming function (display switched OFF).
If the power supply fails for any reason during programming, all the modifi cations you have made will be lost.
To
EXIT
programming:
press the
YELLOW
button until the display is switched OFF
Parameters enabling RESET or operations involving MEMORIES: before the modifi cation is confi rmed the display shows
SURE
,
if confi rmation is given (RED button) fl ashes for 3 sec.
donE
(positive outcome) o
Er
+ error code in the event of failure.
Ö
8 8 8 8
1 2 3 4
YELLOW
DISPLAY
Summary of Contents for SWING 230 APRICODE
Page 63: ...63 SWING 230 APRICODE...